B–16, Restore parameter values from non–volatile storage – Rockwell Automation 1203-SM1 SLC to SCANport Communication Module User Manual
Page 82
SCANport Messaging
B–16
Publication 1203–5.9 –– October 1996
Restore Parameter Values from Non–volatile Storage
The Restore Parameter Values from Non–volatile Storage message
lets you restore the values of all parameters to the values stored in
non–volatile storage. The following is an example of this request:
Service=Restore from Storage
Parameter Class
Instance
Attribute
Data Length=0 Bytes
M0:e.000
M0:e.001
M0:e.002
M0:e.003
M0:e.004
0015
000f
0000
0000
0000
Value
Restore Parameter Values from Non–Volatile Storage
Service=Restore from Storage
Parameter Class
Instance
Attribute
Data Length=0 Bytes
M1:e.100
M1:e.101
M1:e.102
M1:e.103
M1:e.104
0015
000f
0000
0000
0000
Value
Response
Figure B.10 shows a Restore Parameter Values from Non–volatile
Storage request. This message has successfully restored all
SCANport device parameters in RAM from non–volatile storage.
Figure B.10
Example of Restore Parameter Values from Non–volatile Storage
address 0 1 2 3 4 5 6 7 8 9
N10:0 0015 000f 0000 0000 0000 0000 0000 0000 0000 0000
address 0 1 2 3 4 5 6 7 8 9
N11:0 0015 000f 0000 0000 0000 0000 0000 0000 0000 0000