SCANport Messaging

B–16

Publication 1203–5.9 –– October 1996

Restore Parameter Values from Non–volatile Storage

The Restore Parameter Values from Non–volatile Storage message
lets you restore the values of all parameters to the values stored in
non–volatile storage. The following is an example of this request:

Service=Restore from Storage

Parameter Class

Instance

Attribute

Data Length=0 Bytes

M0:e.000

M0:e.001

M0:e.002

M0:e.003

M0:e.004

0015

000f

0000

0000

0000

Value

Restore Parameter Values from Non–Volatile Storage

Service=Restore from Storage

Parameter Class

Instance

Attribute

Data Length=0 Bytes

M1:e.100

M1:e.101

M1:e.102

M1:e.103

M1:e.104

0015

000f

0000

0000

0000

Value

Response

Figure B.10 shows a Restore Parameter Values from Non–volatile
Storage request. This message has successfully restored all
SCANport device parameters in RAM from non–volatile storage.

Figure B.10
Example of Restore Parameter Values from Non–volatile Storage

address 0 1 2 3 4 5 6 7 8 9
N10:0 0015 000f 0000 0000 0000 0000 0000 0000 0000 0000

address 0 1 2 3 4 5 6 7 8 9
N11:0 0015 000f 0000 0000 0000 0000 0000 0000 0000 0000