B–19, Read product number – Rockwell Automation 1203-SM1 SLC to SCANport Communication Module User Manual

Page 85

Advertising
background image

SCANport Messaging

B–19

Publication 1203–5.9 –– October 1996

Read Product Number

The Read Product Number message lets you request the product
number from the SCANport device. The following is an example of
this request:

Service=Get Attribute Single

Internal A–B Vendor Specific Class

Instance

Attribute

Data Length=0 Bytes

M0:e.000

M0:e.001

M0:e.002

M0:e.003

M0:e.004

000e

0092

0000

0000

0000

Value

Read Product Number

Service=Get Attribute Single

Internal A–B Vendor Specific Class

Instance

Attribute

Data Length=6 Bytes

M1:e.100

M1:e.101

M1:e.102

M1:e.103

M1:e.104

000e

0092

0000

0000

0006

Value

Response

Product Number (Value)

Discard

Discard

M1:e.105

M1:e.106

M1:e.107

0003

0000

0000

Figure B.13 shows a Read Product Number request. In this example,
the product number is 3.

Figure B.13
Example of Read Product Number

address 0 1 2 3 4 5 6 7 8 9
N10:0 000e 0092 0000 0000 0000

address 0 1 2 3 4 5 6 7 8 9
N11:0 000e 0092 0000 0000 0006 0003 0000 0000