Read Enum String for Value in Parameter

The Read Enum String for Value in Parameter message lets you
request the text string that corresponds to a specific bit in a specific
parameter. The following is an example of this request:

Service=Get Enum String

Parameter Class

Instance=Parameter #5

Attribute=Value/Bit# = 1

Data Length=0 Bytes

M0:e.000

M0:e.001

M0:e.002

M0:e.003

M0:e.004

004b

000f

0005

0001

0000

Value

Read Enum String for a Value of 1 in Parameter #5

Service=Get Enum String

Parameter Class

Instance=Parameter #5

Attribute=Value/Bit# = 1

Data Length=12 Bytes

M1:e.100

M1:e.101

M1:e.102

M1:e.103

M1:e.104

004b

000f

0005

0001

000c

Value

Response

Enum String (Chars Lo=1st, Hi=2nd)

Enum String (Chars Lo=3rd, Hi=4th)

Enum String (Chars Lo=5th, Hi=6th)

Enum String (Chars Lo=7th, Hi=8th)

Enum String (Chars Lo=9th, Hi=10th)

M1:e.105

M1:e.106

M1:e.107

M1:e.108

M1:e.109

6552

6f6d

6574

5020

746f

Enum String (Chars Lo=11th, Hi=12th)

M1:e.110

2020

Figure B.12 shows a Read Enum String for Value in Parameter
request. In this example, parameter 5 has an Enum string of Remote
Pot
associated with a value of 1. Note that enum strings are all 12
characters long.

Figure B.12
Example of Read Enum String for Value in Parameter

address 0 1 2 3 4 5 6 7 8 9
N10:0 004b 000f 0005 0001 0000 0000 0000 0000 0000 0000

address 0 1 2 3 4 5 6 7 8 9
N11:0 004b 000f 0005 0001 000c 6552 6f6d 6574 5020 746f
N11:10 2020 0000 0000 0000 0000 0000 0000 0000 0000 0000

address 0 1 2 3 4 5 6 7 8 9
N11:0 \00 K \00\0F \00\05 \00\01 \00\0C e R o m e t P t o
N11:10 \00\00 \00\00 \00\00 \00\00 \00\00 \00\00 \00\00 \00\00 \00\00