Publication 1398-5.1 — January 2000

3-2 Wire the ULTRA Plus PDM Components

Figure 3.1
Power Wiring Diagram for 1398-PDM-10, 20, and 30

5

10

9

9

7

9

9

1

3

7

5

4

3

2

1

10

4

A

B

C

D

PIN

SIGNAL

R

S

T

MOTOR CASE

2

9

1

7

3

UL CLASS J,CLASS R OR EQUIVALENT FUSES ARE
ACCEPTABLE, LOCAL REGULATIONS MUST BE OBSERVED.

FUSE

BLOCK

COMMON GROUNDING

POINT FOR AMPLIFIER

SYSTEM (ONE PER AXIS)

MACHINE COMMON

GROUNDING BUS BAR

AC LINE

FILTER

AC LINE

FILTER

TO PROTECTIVE

EARTH TERMINAL

H-SERIES
F-SERIES
N-SERIES

MOTORS

DC BUS

TB1

L2/N AUX

L1 AUX

L2/N

L1

DC-

DC+

R

S

T

TERM

BLOCK

DRIVE

ALL

PDM-10

PDM-20

L1,L2/N,

L1,L2/N,

L1,L2/N,

PDM-30

INPUT (OPTIONAL)

0020-5097.

OF L2 OR L2/AUX, ONLY L1 MAY BE SWITCHED OR FUSED.

NOTE: SLOW BLOW FUSES ARE REQUIRED TO ALLOW FOR INRUSH
CURRENT DURING POWER INITIALIZATION AT THE MAIN
AND AUXILIARY TERMINALS. TIME DELAY VERSIONS OF

21936

__

__

__

__

H-SERIES
F-SERIES
N-SERIES

MOTORS

DC BUS

TB1

FUSE

BLOCK

COMMON GROUNDING

POINT FOR AMPLIFIER

SYSTEM (ONE PER AXIS)

L2/N AUX

L1 AUX

L2/N

L1

DC-

DC+

R

S

T

WIRE SIZES ARE MINIMUM RECOMMENDED VALUES. THE REQUIREMENTS OF LOCAL REGULATIONS SHOULD BE OBSERVED.

AC LINE FILTER AND SHIELDED MOTOR CABLE ARE OPTIONAL. TO BE USED FOR IMPROVING THE DRIVE MODULES ELECTROMAGNETIC COMPATABILITY. THE AUX INPUT HAS AN

INTERNAL FILTER. WIRING BETWEEN THE DRIVE MODULE AND FILTER SHOULD BE KEPT AS SHORT AS POSSIBLE. THE COMMON GROUND BUS BAR SHOULD BE AS CLOSE
TO THE DRIVE AS POSSIBLE.

14 AWG/2.5mmÉ

MULTIPLE DRIVE MODULES MAY BE POWERED FROM ONE TRANSFORMER OR OTHER AC SUPPLY SOURCE.

8.

MOTOR POWER

CONNECTOR MATING

CONNECTOR

MOTOR POWER

DRIVE

MODULE

TERMINAL(S)

L2/N AUX

L1 AUX,

RECOMMENDED

POWER WIRE

(GAUGE/mmÉ)

˚

16 AWG/1.5mmÉ

10 AWG/4mmÉ

14 AWG/2.5mmÉ

AC AUXILIARY POWER

INPUT POWER WIRES

DRIVE ENABLE INPUT MUST BE OPENED WHEN MAIN POWER IS REMOVED AND AUXILIARY POWER IS PRESENT, OR A DRIVE FAULT WILL OCCUR.

DO NOT DAISY CHAIN DRIVE MODULES. MAKE SEPARATE CONNECTIONS DIRECTLY TO THE AC SUPPLY.

DRIVE RATED 100-240 VAC RMS,SINGLE PHASE INPUT VOLTAGE (230 VAC STANDARD).

6.

TRANSFORMER SIZES SHOWN ARE FOR MOST APPLICATIONS: APPLICATIONS REQUIRING MAXIMUM PEAK TORQUE AT MAXIMUM MOTOR SPEED MAY REQUIRE A LARGER TRANSFORMER.

SECONDARY VOLTAGE MAY DROP (BASED ON TRANSFORMER LOAD REGULATION PERFORMANCE) WHEN THE MOTOR DELIVERS PEAK TORQUE. THIS DROP IN TRANSFORMER VOLTAGE WILL

LIMIT MAXIMUM MOTOR SPEED WHILE PEAK TORQUE IS REQUIRED. SEE DRAWING 9101-1057 FOR TRANSFORMER LOAD REGULATION OF RELIANCE MOTION CONTROL TRANSFORMER

A SUPPLY DISCONNECTING DEVICE IS REQUIRED FOR MAINTAINANCE & SAFETY. LOCAL REGULATIONS SHOULD BE OBSERVED. IN EUROPE,IF A GROUNDED NEUTRAL IS USED INSTEAD

MAY BE USED TO KEEP LOGIC SECTION OF DRIVE MODULE SUPPLIES POWERED AFTER MAIN MOTOR SUPPLY IS TURNED OFF AT L1, L2 TERMINALS

JUMPER INSTALLED AT FACTORY FOR INTERNAL SHUNT. SEE DRAWING 9101-1328 FOR TERMINAL WIRING OF EXTERNAL SHUNT OPTION TERMINALS.

(EXAMPLE: TO RETAIN DIAGNOSTIC STATUS OF DRIVE MODULE AFTER L1, L2 POWER DOWN). WHEN USING A THREE PHASE SUPPLY CONNECT THE MAIN
AND AUXILIARY INPUTS TO THE SAME PHASE.

L1,L2/N,

0020-5097

RELIANCE

PART NUMBER

˚

H-2005

1.0 Amps AC at 115 Volts AC
0.5 Amps AC at 230 Volts AC

10.0 AMPS AC
19.0 AMPS AC
28.0 AMPS AC

DRIVE MODULE INPUT CURRENT REQUIREMENTS

IQ TERMINALS

L1 AUX, L2/N AUX

PDM-10
PDM-20
PDM-30

PDM-30

3.0kVA

TRANSFORMER SIZES

SUGGESTED

MOTOR POWER CONNECTOR

MOTOR POWER WIRES R,S,T,GND

MINIMUM

RECOMMENDED

POWER WIRE

(GAUGE/mmÉ)

MOTOR

16 AWG/1.5mmÉ

12 AWG/3.0mmÉ

H-3007

H-3016

H-4030

F-4030

H-4050

F-4050

H-4075

F-4075

MOTOR POWER

MATING CONNECTOR

16 AWG/1.5mmÉ

14 AWG/2.5mmÉ

CONTACT SIZE

(GAUGE/mmÉ)

L1

L2

(OPTIONAL, NOT REQUIRED WHEN
DESIRED INPUT VOLTAGE IS
AVAILABLE DIRECTLY FROM THE
LINE)

TRANSFORMER
CHASSIS

ISOLATION OR AUTO TRANSFORMER

OR CIRCUIT BREAKER

AC LINE

SINGLE PHASE

50/60Hz

FUSED DISCONNECT

TORQUE ALL TERMINALS

TO 11 LB-IN.

TERMINAL STRIP

ACCEPTABLE WIRE RANGE

(GAUGE/mmÉ)

22-10 AWG/0.5-6mmÉ

DRIVE

MODULE

„XCON…

„XCON…

(60˚C COPPER ONLY)

(60˚C COPPER ONLY)

NOTES

POWER WIRING CONNECTIONS

.XXX±.010

DECIMALS.XX±.020

FRACTIONS:±1/64"

DO NOT SCALE DRAWING

ANGLES ±1ANGLES ˚

TOLERANCE ON:

FILLETS AND ROUNDS .02 R MAX

BREAK ALL EDGES .02 MAX

DIMENSIONS ARE IN INCHES

DATE

DATE

C

PART NO.

DWG SIZE

SHEET

SCALE

N/A

of

REV ECOCHKR

DATE

REVISION DESCRIPTION

BY

DESIGN ENGR

DRAWN BY

JM

UNLESS OTHERWISE SPECIFIED

9101-2195

6-3-96

1398-PDM-10,

20, and 30

1

1

JM

A

RELEASED