200 watts, 800 watts, 1800 watts – Rockwell Automation 1398-PDM-xxx ULTRA Plus Series Positioning Drive Module User Manual

Page 78: 900 watts

Advertising
background image

Publication 1398-5.1 — January 2000

3-14 Wire the ULTRA Plus PDM Components

Figure 3.9
External Shunt Wiring Examples

TB2-1

R1

R2

TB2-1

TB2-3

1 - 200W Unit Configuration*

200 Watts

TB2-1

TB2-3

4 - 200W Unit Configuration*

800 Watts

9 - 200W Unit Configuration*

1800 Watts

R1

R1

R2

R3

R4

TB2-1

TB2-3

R1

R3

R4

R6

R7

R9

R2

R5

R8

NOTES:
Uses 200W units p/n 9101-1079
*Configuration good for all ULTRA Plus PDMs

TB2-1

TB2-3

R1

TB2-3

NOTES:

Uses 900W units p/n 9101-1674
*Configuration good for 1398-PDM-075,150, and 150B units
**Configuration good for 1398-PDM-150 and 150B units only

1 - 900W Unit Configuration*

900 Watts

2 - 900W Unit Configuration**

1800 Watts