Figure 3.5 auxiliary power supply connections – Rockwell Automation 1398-PDM-xxx ULTRA Plus Series Positioning Drive Module User Manual

Page 72

Advertising
background image

Publication 1398-5.1 — January 2000

3-8 Wire the ULTRA Plus PDM Components

Figure 3.5
Auxiliary Power Supply Connections

9

9

8

10

8

8

10

9

F3

F2

F1

240VAC,

3 PHASE

CONTROL CIRCUIT
TRANSFORMER

PSM-AUX
TRANSFORMER
0020-5093

240VAC

120VAC

F4

GND

L3

L2

L1

L1

L2

L3

240VAC

120VAC

PSM-AUX

POWER SUPPLY

MODULE (PSM)

DRIVE

MODULE

EXAMPLE:

240V LINE

CUSTOMER'S
120VAC
CONTROL
CIRCUITS

1

2

L3

L2

L1

POS

NEG

GND

T

S

R

POS

NEG

GND

DIAGRAM, OUTLINE & CONNECTION

PSM-AUX, 1398-PDM-25, 50, 100, and 150

9101-0134 REV D1

480VAC, 3 PHASE PRIMARY

240VAC, 3 PHASE SECONDARY

480VAC,

3 PHASE

GND

L3

L2

L1

F4

0020-5091-XXX

L1

L2

L3

480VAC

120VAC

PSM-AUX

CONTROL CIRCUIT
TRANSFORMER

POWER SUPPLY

MODULE (PSM)

DRIVE

MODULE

EXAMPLE:

480V LINE

F3

F2

F1

CUSTOMER'S
120VAC
CONTROL
CIRCUITS

IN THIS EXAMPLE, THE PSM INPUT POWER IS SUPPLIED DIRECTLY FROM THE 3 PHASE LINE.

THEREFORE, THE PSM-AUX INPUT POWER MUST BE ISOLATED FROM AND FROM THE 240V INPUT LINE.

IN THIS EXAMPLE THE PSM-AUX TRANSFORMER SECONDARY MUST NOT BE CONNECTED TO .

SIZE TRANSFORMER FOR 400 VA (PSM-AUX)+ CUSTOMER CONTROL CIRCUIT REQUIREMENTS.

IN THIS EXAMPLE, PSM-AUX INPUT POWER IS CONNECTED TO AT THE CONTROL CIRCUIT

TRANSFORMER SECONDARY. THEREFORE THE PSM INPUT POWER MUST BE ISOLATED

FROM AND FROM THE 480V INPUT LINE. THE THREE PHASE TRANSFORMER PROVIDES

THE ISOLATION AND ALSO STEPS DOWN THE VOLTAGE.

1

2

L3

L2

L1

POS

NEG

GND

T

S

R

POS

NEG

GND

NOTES:

SAMPLE INPUT POWER WIRING CONFIGURATIONS, PSM-AUX WITH 1398-PDM-25, 50, 100, and 150

Advertising