Program setup and operation summary – Rockwell Automation 1746-NR4 SLC RTD/Resistance Input Module User Manual User Manual

Page 114

Advertising
background image

Publication 1746-UM008B-EN-P - December 2006

114 Application Examples

Program Setup and Operation Summary

1. Set up two configuration words in memory for each channel,

one for °C and the other for °F.

2. When the position of the degrees selector switch changes, write

the appropriate channel configuration to the RTD module.

Note that the use of the OSR instruction (one-shot rising) makes
these configuration changes edge-triggered, that is, the RTD unit
is reconfigured only when the selector switch changes position.

3. Convert the individual RTD data words to BCD and send the

data to the respective LED displays.

Channel

Configuration Word Allocation

°F

°C

0

N10:0

N10:4

1

N10:1

N10:5

2

N10:2

N10:6

3

N10:3

N10:7

°C °F

Degrees Selector Switch

Advertising