Install the ac power supply module – Rockwell Automation 2711PC-xxxx PanelView Plus 6 Compact Terminals User Manual User Manual

Page 119

Advertising
background image

Rockwell Automation Publication 2711PC-UM002B-EN-P - April 2014

119

Install and Replace Components

Chapter 5

5. Carefully lift the logic module away from the terminal and turn over to

expose the circuit board.

6. Locate the battery on the circuit board.
7. Remove the battery by lifting up the side of the battery.

The battery can be removed up to 15 seconds without losing clock and
calendar data.

8. Insert the new battery.

9. Reattach the logic module by aligning the two connectors on the bottom

of the logic module with the connectors on the back of the display module.

10. Push down on the logic module until it is firmly seated.
11. Tighten the four captive screws that secure the logic module to a torque

of 0.58 N•m (5…7 lb•in).

12. If necessary, reattach the communication module and torque the four

screws to 0.58 N•m (5…7 lb•in).

Install the AC Power Supply
Module

The AC power supply module, catalog number 2711P-6RSA, attaches to the
back of a DC-powered terminal to convert the terminal from DC to AC power.

Table 36 - AC Power Supply Ratings

You can install the AC module with the terminal mounted in the panel. No
special tools are needed.

Input Voltage

Power Consumption

100…240V AC (50…60 Hz)

35VA max

Advertising