Access Maintenance Operations

Follow these steps to access Maintenance actions at startup.

1. Insert a thin, nonconductive probe into the hole marked DEFAULT on

the back of the logic module and press the switch.

The terminal restarts in Maintenance mode with the display brightness set
to 100%. See

Table 60 on page 151

for a description of maintenance

operations.

2. Press the up and down arrow keys on the keypad or attached keyboard to

move up and down the list of these maintenance options:
Reboot with selection options
Special BOOT Action

TIP

Terminals require an attached USB keyboard to navigate in Maintenance mode.

FAULT

COMM

DEFAULT

RESET

FA

UL

T

COMM

FAULT

DEFAUL

T

RESET

RESET

DEFAULT

COMM
FAULT
DEFAULT
RESET

TIP

To access this menu from a fault state, press the RESET switch, then
press and hold the DEFAULT switch until you see the menu.

Initial Maintenance Window

default button pressed, please select maintenance options

Maintenance Menu -- ver 0x.xx

Special BOOT Action - None

Reboot with selected options

Continue with this system
boot.

This option will continue
booting with the options
selected on the left.

- IMPORTANT----------------------
USB keyboard required!

Press the RESET switch to
ignore changes and continue
system boot.

The version refers to the
boot loader.

TIP

Use the keys at the bottom of the window to make selections.