Connections and Communication

Controller Connections

Table 48

through

Table 51

provides a summary of PanelView Plus 6

Compact connections to controllers and interface modules.

Table 48 - Communication Cables: PanelView Plus 6 Compact Terminals to SLC Controllers

Protocol

PanelView Plus 6 Compact Port

SLC 500, 5/01, 5/02

CH1 RJ45

(DH-485)

SLC 5/03, 5/04, 5/05

CH0 (9-pin RS-232)

(DF1 or DH-485)

SLC 5/03

CH1 (RJ45)

(DH-485)

SLC 5/04

CH1 (DH+)

SLC 5/05

CH1 (ENET)

DF1

RS-232 (DF1) port (9-pin)
All terminals

2711-NC13 (5 m/16 ft)

2711-NC14 (10 m/32 ft)

DH-485

RS-232 (DH-485) port (9-pin)
All terminals

Use AIC+ module

(1761-NET-AIC) to connect to

port 1 or 2

2711-NC13 (5 m/16 ft)

2711-NC14 (10 m/32 ft)

Use AIC+ module

(1761-NET-AIC) to

connect to port 1 or 2

DH-485 port
1000 terminals only
Requires 2711P-RN6, 2711P-RN6K

1761-CBL-AS03

(3 m/10 ft)

1761-CBL-AS09

(9 m/30 ft)

Use AIC+ module

(1761-NET-AIC)

to connect to port 3

1761-CBL-AS03

(3 m/10 ft)

1761-CBL-AS09

(9 m/30 ft)

EtherNet/IP

EtherNet/IP port
All terminals
2711P-RN20 provides additional port -
1000 terminals only

Use 1761-NET-ENI module

with Ethernet cable

1585J-M type cable or

2711P-CBL-EX04

(4 m/14 ft)

Table 49 - Communication Cables: PanelView Plus 6 Compact Terminals to PLC-5 and MicroLogix Controllers

Protocol

PanelView Plus 6 Compact Port

PLC-5, PLC-5C, PLC-5E

CH0 (25-pin RS-232)

(DF1)

MicroLogix 1400, 1500LRP

CH1/CH2 (9-pin RS-232)

(DF1 or DH-485)

MicroLogix 1000, 1100, 1200,

1400, 1500LSP

CH0 (8-pin Mini DIN)

(DF1 or DH-485)

MicroLogix 1100, 1400

Ethernet

DF1

RS-232 (DF1) port (9-pin)
All terminals

2711-NC13 (5 m/16 ft)

2711-NC14 (10 m/32 ft)

(9-to-25 pin adapter required)

2711-NC13 (5 m/16 ft)

2711-NC14 (10 m/32 ft)

2711-NC21 (5 m/16 ft)

2711-NC22 (15 m/49 ft)

(1)

DH-485

RS-232 (DH-485) port (9-pin)
All terminals

2711-NC13 (5 m/16 ft)

2711-NC14 (10 m/32 ft)

2711-NC21 (5 m/16 ft)

2711-NC22 (15 m/49 ft)

DH-485 port
1000 terminals only
Requires 2711P-RN6, 2711P-RN6K

Use AIC+ module

(1761-NET-AIC)

to connect to port 3

EtherNet/IP

EtherNet/IP port
All terminals
2711P-RN20 provides additional port -
1000 terminals only

To PLC-5E with

1585J-M type cable or

2711P- CBL-EX04 (4 m/14 ft)

Use 1761-NET-ENI module

with Ethernet cable

1585J-M type cable or

2711P- CBL-EX04 (4 m/14 ft)

(1)

(1)

The AIC+ module is recommended for isolation purposes when the terminal and controller are not on same power supply.

Table 50 - Communication Cables: PanelView Plus 6 Compact Terminals to Logix Controllers

Protocol

PanelView Plus 6 Compact Port

ControlLogix

CH0 (9-pin RS-232)

(DF1)

CompactLogix

CH0 (9-pin RS-232)

(DF1 or DH-485)

DF1

RS-232 (DF1) port (9-pin)
All terminals

2711-NC13 (5 m/16 ft)

2711-NC14 (10 m/32 ft)

2706-NC13 (3 m/10 ft)

2711-NC13 (5 m/16 ft)

2711-NC14 (10 m/32 ft)

2706-NC13 (3 m/10 ft)

DH-485

RS-232 (DH-485) port (9-pin)
All terminals

2711-NC13 (5 m/16 ft)

2711-NC14 (10 m/32 ft)

2706-NC13 (3 m/10 ft)

DH-485 port
1000 terminals only
Requires 2711P-RN6, 2711P-RN6K

Use AIC+ module

(1761-NET-AIC)

Connect to Port 3

EtherNet/IP

EtherNet/IP port
All terminals
2711P-RN20 provides additional port -
1000 terminals only

Use 1756-EN2T or 1756-ENBT module with

1585J-M type cable or

2711P- CBL-EX04 (4 m/14 ft)

To 1769-L35E, 1769-L23E, 1769-L32E,

or 1768-ENBT module with 1585J-M type cable

or 2711P- CBL-EX04 (4 m/14 ft)