Rockwell Automation 2711PC-xxxx PanelView Plus 6 Compact Terminals User Manual User Manual

Page 23

Advertising
background image

Rockwell Automation Publication 2711PC-UM002B-EN-P - April 2014

23

Install the Terminal

Chapter 2

3. Place the terminal in the panel cutout.

4. Insert all mounting levers into the mounting slots on the terminal.

Slide each lever until the flat side of the lever touches the panel surface.

5. When all levers are in place, slide each lever an additional notch or two

until you hear a click.

Refer to

Table 15 on page 22

as a guide to determine the locking positions

for your panel thickness.

6. Rotate each lever in the direction indicated until it is in the final position.

Follow the appropriate locking sequence for the optimal terminal fit.

7. Inspect all levers to verify that they are in the correct and same locked

position.

6

1

6

1

Flat Side of Lever

Mounting Slots

Mounting Levers

TIP

Levers rotate in same direction on top and bottom of terminal.

FAULT

COMM

DEFAULT

RESET

FA

U

LT

Notch

Rotate lever until notch in lever aligns with
proper alignment mark on terminal.

Alignment Marks

6

1

1

3

4

2

ATTENTION: All levers must be locked to provide an adequate gasket
seal between the terminal and the panel. Rockwell Automation
assumes no responsibility for water or chemical damage to the terminal
or other equipment within the enclosure because of improper
installation.