62 Specifications
Inputs
6 Channels
Isolation
Sensitivity
Input Range
Input Impedance
1 to 6 process DC voltage inputs or loop
current inputs
Up to 250 Volts of isolation for each input
User configurable in software.
User configurable per channel as:
0 to 5 Volts
0 to 10 Volts
4 to 20mA
-5 to 5 Volts
1 to 5 Volts
0 to 20mA
50 ohm Current input / 1 Mohm voltage
input
Outputs
4-20mA Outputs
Accuracy
Isolation
Two isolated banks of three outputs (one
per channel)
600 ohm max load
±1% of full scale max
±0.2% of full scale typical
250 Volts
Indicators
8 LEDs Module Status - red/green
Network Status - red/green
Channel 1 Status - yellow/red
Channel 2 Status - yellow/red
Channel 3 Status - yellow/red
Channel 4 Status - yellow/red
Channel 5 Status - yellow/red
Channel 6 Status - yellow/red
XM-360 Technical Specifications
Product Feature