72 DeviceNet Information

The Poll response data can also be requested explicitly through Assembly
Object (Class ID 0x4), Instance 101 (0x65) – 103 (0x67), Data Attribute (3).

The following tables show the static data format of Assembly instance 101–
103.

XM-360 Assembly Instance 101 Data Format

Byte

Definition

0–3

Channel 1 measurement value

4–7

Channel 2 measurement value

8-11

Channel 3 measurement value

12-15

Channel 4 measurement value

16-19

Channel 5 measurement value

20-23

Channel 6 measurement value

24-27

Channel 1 rate of change value

28-31

Channel 2 rate of change value

32-35

Channel 3 rate of change value

36-39

Channel 4 rate of change value

40-43

Channel 5 rate of change value

44-47

Channel 6 rate of change value

XM-360 Assembly Instance 102 Data Format

Byte

Definition

0–3

Channel 1 rate of change value

4–7

Channel 2 rate of change value

8-11

Channel 3 rate of change value

12-15

Channel 4 rate of change value

16-19

Channel 5 rate of change value

20-23

Channel 6 rate of change value

24-27

Channel 1 measurement value

28-31

Channel 2 measurement value

32-35

Channel 3 measurement value

36-39

Channel 4 measurement value

40-43

Channel 5 measurement value

44-47

Channel 6 measurement value