2 enclosure ratings, 3 b-frame liquiflo drive component locations – Rockwell Automation Liqui-Flo AC Power Modules User Manual

Page 14

Advertising
background image

2-2

LiquiFlo AC Power Modules, Hardware Reference Version 6.4

Table 2.1 – Power and Enclosure Ratings

* With V/Hz regulation, 110% continuous output current capability. With vector regulation, 150% output current capability for 5 sec.

**Note that LiquiFlo drives are rated for use with water at specified temperatures and pressures as the coolant. Some coolant fluids may

allow an increased output rating while others may require the output to be derated. The LiquiFlo drive is also capable of running at 4 kHz
or 8 kHz. Contact Reliance Electric for ratings.

2.2

Enclosure Ratings

LiquiFlo drives have the following enclosure rating:

Open-Chassis Style: Intended to be installed in an enclosure.

LiquiFlo drives must be placed in an enclosure.

2.3

B-Frame LiquiFlo Drive Component Locations

The B-Frame LiquiFlo drives have the following main components. The numbered
items listed below provided correspond to the numbers used in figure 2.2.
Replacement parts are listed in chapter 9.

Model

Number

Frame Size and

Selected

Regulation*

Enclosure

Rating

Input

Power

(KVA)

Input

Current

(Amps)

Output Current

at 2 kHz**

(Amps)

Full Load

Power Loss Watts

Fluid / Air

41L4060

41LR4060

B-Frame

V/Hz or Vector

Open-Chassis

Style

344

414

414

4600 / 1100

50LW4060

50LR4060

C-Frame

V/Hz or Vector

Open-Chassis

Style

398

500

500

5500 / 1500

64LW4060

64LR4060

C-Frame

V/Hz or Vector

Open-Chassis

Style

512

643

643

7000 / 2000

120L4060

D-Frame

V/Hz or Vector

Open-Chassis

Style

956

1200

1200

11700/4000

1.

Bus Bars (3) (AC Output)

2.

Bus Bars (6) (AC Input)

3.

IGBT Modules

4.

Output Laminate

5.

Capacitors

6.

RMI Board

7.

Casting

8.

Membrane Switch Keypad

9.

Coolant Lines - (a) Inlet, (b) Outlet

10.

Regulator Board

11.

Power Module Control (PCB)

12.

Current Feedback Devices (3)