Cooling System Specifications

B-1

A

PPENDIX

B

Cooling System Specifications

M/N 41L4060 M/N 41LR4060

M/N 50LW4060
M/N 64LW4060

M/N 50LR4060
M/N 64LR4060

M/N 120L4060

Coolant Type

Potable water
with no
additives.

Refrigerant

Potable water
with no
additives.

Refrigerant

Potable water
with approved
corrosion

inhibitor

1

.

1

Approved corrosion inhibitor: Chemtool, Inc., Crystal Lake, IL., part number CT787-C. Concentration is 2% by volume.

Inlet Coolant
Temperature Range

15

o

C to 40

o

C

(60

o

F to

104

o

F)

2

2

Coolant temperature should be greater than the dew point of the surrounding air to prevent condensation on the tubing and heatsink.

See note

3

.

3

Contact Reliance Electric for coolant circuit requirements.

15

o

C to 40

o

C

(60

o

F to

104

o

F)

2

See note

3

.

15

o

C to 40

o

C

(60

o

F to 104

o

F)

2

Minimum Coolant Flow
Rate at Full Load

7.0 gpm

See note

3

.

5.0 gpm

See note

3

.

8.0 gpm

Differential Coolant
Pressure at Minimum
Flow Rate

3.0 psi

See note

3

.

34.0 psi

See note

3

.

5.0 psi

Maximum Inlet
Pressure

450 psi

See note

3

.

300 psi

See note

3

.

50 psi

Maximum Heat Load

16,000
BTU/hour

16,000
BTU/Hour

25,000
BTU/hour

25,000
BTU/Hour

40,000
BTU/hour

Advertising