General monitor problems – ADS Environmental Services RainAlert II QR 775008 A2 User Manual

Page 118

Advertising
background image

6-12

ADS RainAlert II Manual

General Monitor Problems

The following tables contain general techniques for troubleshooting
the ADS RainAlert II monitor.

Problem

Time stamp on the collected data is incorrect.

Possible

Causes

PC clock may read incorrect time.

Monitor clock may be faulty.

Possible

Solutions

Verify the time on the PC clock and correct if necessary.

Reactivate the monitor to enable the clock.

Collect the data from the monitor and replace monitor if
defective.

Problem

Time on the monitor clock is incorrect.

Possible

Causes

Monitor clock may be faulty.

PC clock may read incorrect time.

Possible

Solutions

Verify the time on the PC clock and correct if
necessary.

Reactivate the monitor to enable the clock.

Collect the data from the monitor and replace monitor if
defective.

Problem

You receive a Device Time Out message in Profile.

Possible

Cause

Circuit board may be faulty.

Possible

Solutions

Re-attempt communication with monitor.

Replace the monitor if defective.

Contact your regional ADS representative.