Editing the notification device – ADS Environmental Services RainAlert II QR 775008 A2 User Manual

Page 76

Advertising
background image

Configuration and Activation 5-9

Rain Per Tip Enter the amount of rain that must accumulate
in the tipping bucket to initiate one tip of the tipping
mechanism.

Rain Intensity Interval Enter the amount of time within
which a specified amount of rain must fall to initiate a rain
alarm.

Enable Select this checkbox to activate the options to edit
parameters and to ensure Profile configures the monitor to
initiate and terminate an alarm under the rain conditions
designated in the Rain Alarm section.

Threshold Enter the rain amount over a designated interval
at which you want the monitor to initiate an alarm and contact
an ADS IntelliServe

system, an email recipient, and/or a

cellular telephone that receives text messages.

Return to Normal Enter the rain amount that cannot be
exceeded over a designated interval to ensure the monitor
discontinues an existing rain alarm. Under this scenario, the
monitor also contacts an ADS IntelliServe system, an email
recipient, and/or a cellular telephone that receives text
messages that conditions have returned to normal.

Editing the Notification Device

The RainAlert II monitor can provide rain alarm notification
through IntelliServe systems, email, and cellular phones with text
messaging (SMS) capability. The RainAlert II also can check in
daily and provide event notification to an email address and cellular
phone. Events concern low battery voltage, power failure, and time
errors.