Communication

4-23

8. Close and secure the front cover of the module.

9. Cut ½ inch of insulation from the loose end of the black ground

wire running from the lightning protection module.

10. Clamp the exposed ground wire to the telephone company’s

ground source.

Wiring the Lightning Protection Module to the
Network Interface Box

The final step in establishing telephone service is wiring the
lightning protection module to the telephone company’s network
interface box. Accomplish this task in the following way:

1. Open the front cover of the telephone company's network

interface box, and temporarily disconnect the test plug.
Opening some network interface boxes may require a special
tool available only through the telephone company.

2. Remove 3 inches of insulation from the lightning protection

module service cable to expose the four insulated wires.

3. Cut off the black and yellow wires (running from the lightning

protection module) down to the level of the external insulation.

4. Strip ½ inch of insulation from the green and red wires.

5. Slice a hole in the rubber grommet in the bottom of the network

interface box (when necessary), and run the wires up through
the grommet into the box.

6. Loosen the screws for tip and ring in the network interface box.

Wrap the following wires around the designated posts and then
re-tighten the screws until snug:

 Red wire

 tip

 Green wire

 ring