Wiring the telephone cable to the monitor – ADS Environmental Services RainAlert II QR 775008 A2 User Manual

Page 60

Advertising
background image

Communication

4-19

Stripping ½ inch of insulation from each wire

5. At the service end of the cable, fold over both exposed wires

(doubling the thickness). Insert each wire into a non-insulated
#10 ring terminal lug (22-18 gauge), and crimp the wires to the
lugs.

Wiring the Telephone Cable to the Monitor

After preparing the telephone cable, wire the telephone cable to the
monitor in the following way:

Note: Wiring the telephone cable to the monitor requires
an intermediate cable (External Power/Phone Cable - ADS
p/n 5000-0697) supplied by ADS when ordering a
RainAlert II monitor equipped for landline communication.

1. Unpack the RainAlert II phone cable (ADS p/n 5000-0697;

same cable as the FlowAlert phone cable and the FlowShark
External Power cable
). The pigtail consists of two bundled
pairs; green/white and red/black. If these soldered junctions
are modified or stripped to make the phone junction easier, be
sure to keep these pairs together. It is not necessary to solder

Advertising