Part 2 - Operating Information

HB-0846-03

2-10

2.5

EXAMPLES OF CALIBRATION

The method of calibration of your HS 2000 System should be made
clear by the following examples. The Calibration Process is
described in detail in Part 3 - Calibration.

2.5.1

Calibration Adjustment - Boat Speed
(1) Using the Scroll Up or Scroll Down Keys select the
upper or lower display as required.
(2) If BOAT SPD (or STD LOG) is shown in the upper
display, press and hold the Scroll Down Key to select
CALBRATE from the menu. If BOAT SPD (or STD LOG) is
shown in the lower display use Scroll Up.
(3) Press Enter and then press Scroll Down to select
MANL CAL on the display.
(4) Press Enter, SINGLE is shown on the Display.
(5) Press Enter to view the current calibration value in
Hz/knot.
(6) To adjust the calibration value, press Enter and the
value flashes.
(7) Use the Scroll Up and Scroll Down Keys to change
the calibration value to the new calibration value.
(8) Press Enter to store the new calibration value into the
system.
(9) Press Page to return to the normal display.

2.5.2

Calibration Adjustment - Depth
(1) Using the Scroll Up or Scroll Down Keys select the
upper or lower display as required.
(2) If DEPTH is shown in the upper display, press and hold
the Scroll Down Key to select CALBRATE from the menu.
If DEPTH is shown in the lower display, use Scroll Up.
(3) Press Enter, the display shows DATUM, which flashes.
(4) Press Enter again, DATUM stops flashing and the
current datum value is displayed.
(5) Press Enter, the DATUM value flashes.
(6) Use Scroll Up or Scroll Down Keys to set the new
DATUM value.

Note
If DATUM is referenced to the water line, the value is positive. If