B&G HS2000 User Manual

Page 61

Advertising
background image

HS 2000 User Manual
Part 4 - Installation Information

HB-0846-03

4-12

8-BUTTON NMEA FULL FUNCTION

DISPLAY INSTALLATION SHEET





INSTALLATION NOTES

??

An NMEA FFD can be connected at any point on the system network. Typically an NMEA
FFD is mounted close to the NMEA device, e.g. at the chart table next to the GPS, thus
minimising the NMEA cable routes.

??

NMEA FFD's can be used in combination with all other display types; i.e. standard FFD's,
Halcyon displays, 20/20 and Pilot displays.


SCREENED CABLES

??

Shielded NMEA cables are supplied to provide protection against unwanted emissions
(EMC) and must be connected in accordance with these instructions.

??

NMEA cable shields must be connected at the TRANSMITTING end.

??

The NMEA output cable shield should be connected to the other cable shields in the
junction box supplied.


NETWORK TERMINATION

??

If the NMEA FFD is the last unit on the system network a network terminator MUST be
fitted across the network data wires; i.e. between the green and white wires. Only two
network terminators are required per system.

NMEA FFD

CABLE FUNCTION

FFD CABLE

COLOUR

SYSTEM

NETWORK

NMEA

INPUT

NMEA

OUTPUT

REMOTE

BUTTON

Network Data -ve

Green

Green

-

-

-

Network Data +ve

White

White

-

-

-

Network Cable Shield

Shield

Shield

-

Shield

-

Ground

Black

Black

-

Blue

Blue

Supply +ve

Red

Red

-

-

-

NMEA Input Signal

Brown

-

Red

-

-

NMEA Input Return

Blue

-

Blue

-

-

NMEA Output Signal

Violet

-

-

Red

-

Remote Control Button

Yellow

-

-

-

Red