B&G HS2000 User Manual

Page 41

Advertising
background image

HS 2000 User Manual

Part 3 - Calibration

HB-0846-03

3-5

3.2.5

Log AUTO CAL Procedure
(1) Select BOAT SPD on the display.
(2) If BOAT SPD is in the upper display, press and hold
Scroll Down to select CALBRATE. If BOAT SPD is in
lower display, use Scroll Up to select CALBRATE.
(3) Press Enter, the display shows the current boat
speed reading with AUTO CAL flashing.
(4) Press Enter, the display shows the current boat
speed reading with SINGLE flashing.
(5) Press Enter twice, the display shows the default
setting for the actual calibration distance for each run
along the given course.
(6) Press Enter, the CAL DIST will flash. The Scroll
Up
and Scroll Down Keys can now be used to select the
appropriate measured distance. Press Enter to accept
the new distance. The system is now ready to start the
first calibration run.
(7) Press Scroll Down, STRT RUN appears flashing.
(8) When crossing the first transit mark of the run,
press Enter, the display now shows the current boat
speed reading with STOP RUN flashing.
(9) When crossing the transit mark at the end of the run
press Enter, the display shows the current boat speed
reading with END CAL flashing.
(10) Press Scroll Down to select STRT RUN again,
then repeat steps (8) and (9).
(11) If only two runs are required, press Enter to end
calibration. The lower display will now show the new
calibration value which has automatically been calculated
by the computer unit. This should be recorded on the
chart provided.
(12) If a third run is required, press Scroll Down to
select STRT RUN, then repeat from step (8).

The boat's log is now calibrated and the new calibration value is
stored permanently in the computer unit's memory.

Note
“Err” will be displayed if the system encountered a problem during
the calibration run. For example, if the cal’ distance was too short.

Advertising