PART 6 - DIAGNOSTIC DATA

6.1

FFD DIAGNOSTICS

The FFD program contains a number of diagnostic functions which
allow the FFD keys, display and memory to be tested, and also
performs checks on other components of the system via the
network. One of the more useful of these tests enables the user to
determine the software version numbers of the processor units in
the system. This information is useful when liaising with Service
Agents.

6.1.1

Diagnostic Function Selection

The diagnostic functions are selected as follows:

(1) When switching on the system press Enter until
DIAGNOST appears in the upper text window.
(2) Press Enter again, the first Test option KEYTEST
appears.
(3) The required test is then selected using the Scroll
Up
and Scroll Down Keys.
(4) Press Enter to start the required test.
(5) On completion of each test press Scroll Up or Scroll
Down
to scroll to the next test. Press Enter to start the
test.
(6) To return the display back to normal operation press
the Page Key.
(7) Provided that the power is not switched off or a
system reset is not performed, the diagnostics can be re-
entered by holding Enter down and pressing the On/Off
Lights Key.

The options available from the DIAGNOSTICS Menu are
described in Paragraphs 6.1.2 to 6.1.13.

6.1.2

Key Test

The display requests the user to press each key in turn as follows:

Key 1

Enter

Key 2

Scroll Down

Key 3

Scroll Up

Key 4

Page

Key 5

On/Off Illumination

Key 6

Speed/Depth

Key 7

Wind

Key 8

Navigation

Advertising