B&G HS2000 User Manual

Page 43

Advertising
background image

HS 2000 User Manual

Part 3 - Calibration

HB-0846-03

3-7

(6) Press Enter, the lower text now shows CAL VAL 1
flashing.
(7) Press Scroll Down repeatedly, and the lower text
will cycle through CAL1 VAL 1, CAL VAL 2, and CAL
VAL 3
When CAL VAL 1 is displayed:
(8) Press Enter, the lower text shows SPD KTS.
When CAL VAL 2 is displayed:
(9) Press Enter, the lower text shows SPD MPH.
When CAL VAL 3 is displayed:
(10) Press Enter, the lower text shows SPD KPH.
For whichever selection is made:
(11) Press Enter, the lower text now shows SPD KTS,
SPD MPH, or SPD KPH with the current boat speed
value in the original units.
(12) Press Enter, the current boat speed value, in the
original units, will flash.
(13) Press Enter, the current boat speed will be
converted to and displayed in the newly selected units.

3.3

COMPASS CALIBRATION

3.3.1

Principles of Compass Calibration (Super Halcyon 3

& Halcyon 2000 Compasses)


B&G's Autoswing Compasses contain software that allows them to
record the magnetic fields in the yacht that are causing the
deviation errors. It calculates the corrections every time the boat
completes a 540° turn - Super Halcyon 3 or 360

?

turn - Halcyon

2000, provided the following conditions are met:

(a) The 540° turn - Super Halcyon 3 or 360

?

turn -

Halcyon 2000 is completed in the same direction.

(b) The rate of change of heading does not exceed 3°/s;
i.e. the turn should take about 3 minutes to complete.

(c) The rate of change of heading must not fall below 0.2
of a degree per second during the 540° turn - Super
Halcyon 3, i.e. the 540° turn must not take longer than 45
minutes.