83 xx

The Locate Fiducial Command failed with no target found. This failure happens most likely during an initial installation
of the Library Subsystem.

Ensure that all fiducial labels are present on Mailbox, storage columns, magazines, and drives. Replace the components that do not
have a fiducial label.

Clean all Teach Fiducial labels.

Contact Dell Customer Support

.

89 xx

Failure was detected while communicating with the Motion Controllers.

Contact Dell Customer Support

.

8A xx

The returned sense indicated that a motion command completed sooner than expected.

Check the Y axis for binding. Binding can be caused by an object that prevents the Y axis from homing and reaching its target
correctly.

Contact Dell Customer Support

.

8B xx

Servo Failures detected in the Rotary and/or Reach axes.

Contact Dell Customer Support

.

93 xx

A failure was detected in the drive communication hardware within the Library: the Library cannot communicate with
one or more drives (note the physical location of the failing drive, this information is presented with the SAC).

If the accompanying message indicated that the Library cannot communicate with one specific tape drive:

l

Re-seat the drive in question by loosening the two thumbscrews, remove the drive and re-install it in the same drive slot.

l

Replace the failing Tape Drive Module.

94 xx

Communication was previously established between the Library and the tape drive but the Library detected that
communication is no longer present or the drive status is not as expected.

NOTE: The coordinates of the failing tape drive sled are posted on the Operator Panel, but if this information was reset by

the operator, it can be retrieved by going to the error log and referring to the error modifier "xxxx". This value will show the failing
drive.

If the SAC modifier "xx" = "00":

l

Re-seat the drive in question by loosening the two thumbscrews, remove the drive and re-install it in the same drive slot.

l

Check to see if there is a cartridge in the failing tape drive that prevents the drive from becoming ready: Eject the cartridge
and retry the operation then replace the Tape Drive Module if appropriate.

Contact Dell Customer Support

.

95 xx

The Picker Assembly delivered a cartridge to a tape drive but the drive does not confirm tape loading status. The "xx"
part of the SAC identifies the drive.

Retry the operation by manually loading a cartridge into the tape drive. Replace the failing Drive Module if this operation failed.

Contact Dell Customer Support

.

98 xx

The firmware variant installed on the tape drive is not supported by the Library. The "xx" part of the SAC identifies the
drive.

If the user has a certified spare tape drive module available, replace the suspect tape drive module.

Contact Dell Customer Support

.

A0 00

The Main Controller and Remote Management Unit failed to establish communication.

Ensure that the Remote Management Unit is securely installed and properly connected.

Contact Dell Customer Support

.

A1 xx

The Library Main Controller established, but then lost communications with one of the auxiliary controllers.

Contact Dell Customer Support

.

A2 xx

Communication was initially established but is now lost between the Main Controller PCBA and the Picker Control
PCBA.

Contact Dell Customer Support

.

A3 xx

Communication was initially established but is now lost between the Main Controller PCBA and the Display Control
PCBA.

Contact Dell Customer Support

.

The Library detected that a fan has failed in one of the DC Power Supplies.

Advertising