Disconnect the belt drive from the dyno drums – Dynojet 424 Linx: DWRT Installation Guide User Manual

Page 45

Advertising
background image

4 2 4 L I N X I N S T A L L A T I O N

Disconnect the Belt Drive from the Dyno Drums

Version 6

Linx Installation for Model 424 Automotive Dynamometers

41

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DISCONNECT THE BELT DRIVE FROM THE DYNO DRUMS

The Linx belt can be disengaged by pulling the splined shafts out of the dyno splines.
1

Loosen the three finger screws and lower the access panel.
For in ground dynos, remove the six 1/4-20 x 5/8-inch torx screws securing each
access cover and set aside. Remove each access cover and set aside.

2

Remove the two 1/4-20 x 1.75-inch cap screws and two 1/4-inch lock washers from
each shaft.

3

Thread the 1/4-20 x 1.25-inch cap screws into the threaded holes on the splined
shaft flange.

4

Tighten the cap screws until the tapered pins disengage from the tapered holes.

5

At each drum, pull the splined shaft out at least four inches.

Always disengage the belt drive at BOTH dynos.

Figure 37: Disconnect the Belt Drive from the Dyno Drums

XD084

threaded holes