103

10.13 Specifications

Power

Line Voltages

115 or 230 VAC

Frequency

50 or 60 Hz

Power Consumption

25 watts maximum

A/D Specifications

Excitation Voltage

10 ± 0.5 VDC,
16 x 350

 or 32 x 700 load cells per A/D card

Sense Amplifier

Differential amplifier with
4- and 6-wire sensing

Analog Signal Input Range –6 mV to +40 mV
Analog Signal Sensitivity

0.3

V/grad minimum @ 7.5 Hz

1.0

V/grad typical @ 120 Hz

4.0

V/grad typical @ 960 Hz

A/D Sample Rate

7.5–960 Hz, software selectable

Input Impedance

>35 M

 typical

Internal Resolution

8 000 000 counts

Wt Display Resolution 9,999,999
Input Sensitivity

10 nV per internal count

System Linearity

±0.01% of full scale

Zero Stability

±150 nV/°C, maximum

Span Stability

± 3.5 ppm/°C, maximum

Input Voltage Differential ±800 mV referenced to earth ground
Input Overload

Load cell signal lines ±10 V continuous, ESD protected

RFI/EMI Protection

Communications, signal, excitation, and sense lines protected

Digital Specifications

Microcomputer

Motorola ColdFire

®

MCF5307 main processor @ 90 MHz

Digital I/O

8 I/O channels on CPU board; optional 24-channel I/O expansion card available

Digital Filter

Software selectable: 1–256, enhanced Rattletrap

®

hybrid digital filtering

Serial Communications

Serial Ports

Ports on CPU board support up to 115200 bps; optional dual-channel serial expansion card available

Port 2

Full duplex RS-232 with CTS/RTS

Port 4

Full duplex RS-232; 2-wire RS-485, 20mA