5 custom stream formatting, Custom stream formatting, Section – Rice Lake 820i Programmable Indicator/Controller - Installation Manual User Manual

Page 98: 94 for information about, See section, 94 for more information about custom, Section 10.5

Advertising
background image

94

820i

Installation Manual

10.5 Custom Stream Formatting

Each port can be independently configured to stream a default frame format or can be customized to stream a

user-defined format. Custom formatting is very similar to the standard print formatting described in Section

6.0.

Table

10-7 on page

94 lists the format identifiers used to configure a custom stream format.

Format Identifier

Defined By

Description

<P[G | N | T]>

STR.POS#n
STR.NEG#n

Polarity. Specifies positive or negative polarity for the current or
specified (Gross/Net/Tare) weight on the source scale. Possible
values are SPACE, NONE, + (for STR.POS#n), or – (for STR.NEG#n)

<U[P | S | T]>

STR.PRI#n
STR.SEC#n
STR.TER#n

Units. Specifies primary, secondary, or tertiary units for the current or
specified weight on the source scale.

<M[G | N | T]>

STR.GROSS#n
STR.NET#n
STR.TARE#n

Mode. Specifies gross, net, or tare weight for the current or
specified weight on the source scale.

<S>

STR.MOTION#n
STR.RANGE#n
STR.OK#n
STR.INVALID#n

Status for the source scale. Default values and meanings for each
status:
STR.MOTION#n

M

In motion

STR.RANGE#n

O

Out of range

STR.OK#n

<space>

OK

STR.INVALID#n

I

Invalid

<B [–]n,…>

See descriptions below

Bit fields. Comma-separated sequence of bit field specifiers. Must
be exactly 8 bits. Minus sign ([–]) inverts the bit.

B0

Always 0

B1

Always 1

B2

Configuration

=1 if even parity

B3

Dynamic

=1 if MODE=NET

B4

Dynamic

=1 if COZ

B5

Dynamic

=1 if standstill

B6

Dynamic

=1 if gross negative

B7

Dynamic

=1 if out of range

B8

Dynamic

=1 if secondary/tertiary

B9

Dynamic

=1 if tare in system

B10

Dynamic

=1 if tare is keyed

B11

Dynamic

=00 if MODE=GROSS
=01 if MODE=NET
=10 if MODE=TARE
=11 (not used)

B12

Dynamic

=00 if UNITS=PRIMARY
=01 if UNITS=SECONDARY
=10 if UNITS=TERTIARY
=11 (not used)

B13

Configuration

=00 (not used)
=01 if current DSPDIV=1
=10 if current DSPDIV=2
=11 if current DSPDIV=5

B14

Configuration

=00 (not used)
=01 if primary DSPDIV=1
=10 if primary DSPDIV=2
=11 if primary DSPDIV=5

B15

Configuration

=00 (not used)
=01 if secondary DSPDIV=1
=10 if secondary DSPDIV=2
=11 if secondary DSPDIV=5

B16

Configuration

=00 (not used)
=01 if tertiary DSPDIV=1
=10 if tertiary DSPDIV=2
=11 if tertiary DSPDIV=5

Table 10-7. Custom Stream Format Identifiers