1.3

Softkey Operations

Softkeys can be defined to provide additional operator functions for specific applications. Softkey assignments are

listed on the tabs shown at the bottom of the LCD display; softkey functions are activated by pressing the arrow

keys below the softkey tabs (Figure

1-1 on page

3).

The particular set of softkeys shown on the display is determined by the indicator configuration and program.

Table 1-1. Configurable Softkeys

Softkey

Description

Time/Date

Displays current time and date; allows time and date change.

Display Tare

Displays tare value for the current scale

Display Accum

Displays accumulator value, if enabled, for the current scale.

Display ROC

Displays rate-of-change value, if enabled, for the current scale.

Setpoint

Displays a menu of configured setpoints; allows display and change of some setpoint parameters.

Batch Start

Starts a configured batch.

Batch Stop

Stops a running batch and turns off all associated digital outputs. Requires a batch start to resume
processing.

Batch Pause

Pauses a running batch. (Same as stop, but digital outputs, if on, are not turned off.)

Batch Reset

Stops a batch and resets it to the first batch step.

Weigh In

Allows truck ID entry; generates weigh-in ticket for truck weighing applications.

Weigh Out

Allows truck ID entry; generates weigh-out ticket for truck weighing applications.

Truck Regs

Displays truck register; allows deletion of individual or all entries. Truck register can be printed by pressing
the PRINT key while the truck register is displayed.

Unit ID

Allows display or change of Unit ID.

Select Scale

For multi-scale applications, provides a prompt to enter the scale number to be displayed.

Diagnostics

Provides access to diagnostic displays for attached

iQUBE

junction boxes.

Alibi

Allows previous print transactions to be recalled and reprinted.

F1–F10

User-programmable keys; defined by application.

More…

For applications with more than five defined softkeys, the More… key is automatically assigned to the fifth
softkey position. Press More… to toggle between groups of softkeys.

1.4

System Configurations and Options

Table 1-2 lists the

820i

system models and part numbers. All models include CPU board with one option card

slot. Each model comes equipped with a single- or dual-channel A/D.

Table 1-2. Part Numbers for 820i Models

System Model

Model PNs

Single-Channel A/D

Dual-Channel A/D

Universal (tilt stand) model, 115 VAC

91995

93011

Universal (tilt stand) model, 230 VAC, North American, NEMA 15-5 power cord

91996

93012

Universal (tilt stand) model, 230 VAC, European, CEE 7/7 power cord

91997

93013

Panel mount model, 115/230 VAC (power cord sold separately)

93424

93425