16

820i

Installation Manual

Serial commands duplicate the functions available

using the indicator front panel and provide some

functions not otherwise available. Serial commands

can be used to simulate pressing front panel keys, to

configure the indicator, or to dump lists of parameter

settings. See Section 9.0 on page 79 for more

information about using the serial command set.

3.1.3

Front Panel Configuration

Use the CONFIG submenu under the SCALES menu

to configure A/D scales. For example, in an indicator

with a single-channel A/D card installed in Slot 1, the

Scale Configuration display will show the A/D listed

(

Slot 1 Channel 1

) under the

AVAILABLE A/D’s

column.

Use the

left

navigation key to select the A/D, then

press the center softkey,

Add

. The A/D is then moved

to the Associated A/D’s column. If no other A/D’s are

listed in the

AVAILABLE A/D’s

column, the center

softkey changes to

Done

, as shown in Figure 3-2.

Press

Done

to exit the Scale Configuration display.

See Section 10.3 on page 93 for information about

configuring serial scales.

05/24/2006

02:22PM

Change

Type

Done

CONFIG

SCALE 1

SCALE 2

Scale 1

Scale 2
Scale 3

SCALES ASSOCIATED

A/D’s

AVAILABLE A/D’s

Slot 1 Channel 1

Figure 3-2. Scale Configuration Display

3.1.4

Multi-Range and Multi-Interval Scales

The

820i

supports multi-range and multi-interval

scales of either two or three ranges or intervals.
Multi-range scales provide two or three ranges, each

extending from zero to the maximum capacity

specified for the range, that can specify different scale

intervals (graduations). The scale interval changes as

the applied weight increases but does not reset to

lower range intervals until the scale returns to zero.
Multi-interval scales divide the scale into two or three

partial weighing ranges, each with different scale

intervals. The scale interval changes with both

increasing and decreasing loads applied.
To configure a multi-range or multi-interval scale, use

the SPLIT parameter to select 2RNG or 3RNG (for

multi-range scales), or 2INTVL or 3INTVL (for

multi-interval scales). Selecting a SPLIT value other

than OFF allows specification of decimal point,

display divisions, and maximum capacity for each

range or interval.

The SPLIT parameter is used to enable multi-range or

multi-interval. The SPLIT parameter is in the

SCALES menu, see Figure 3-4, and Table 3-2. After

setting the SPLIT parameter, the

Format

menu

selection will change as shown in Figure 3-6, and

Table

3-4.

If using streaming with multi-range or multi-interval,

the stream must be set to Custom in

Revolution

. The

Tokens for Secondary and Tertiary Units must be set

to L or K to match the Primary, refer to the Serial

Menu, Tokens Parameter, in Section

3.2.2 on page

30.

They can be set using

Revolution

or through the front

panel.
In multi-range, each range has its own capacity and

display division, extending from zero. The scale

display division will increase at the entered range

capacities, either two or three ranges. Once the range

has increased to the next level, the display division

will remain in new range until the scale returns to

zero. The tare value can be taken in any range.
For example,

Range 1 is 0 - 3000 x 1 lb.
Range 2 is 0 - 10,000 x 5 lb.

In multi-interval, the scale has one capacity, which is

segmented into weighing intervals, either two or three

intervals, each with different display division sizes.

As the weight value exceeds an interval or set interval,

the display division will increase, as the weight falls

below an interval or set interval, the display division

will decrease. The tare can only be taken in the first

interval.
For example,

Range 1 is 0-30 x 0.01 lb.
Range 2 is 30 - 60 x 0.02 lbs.

3.1.5

Total Scale Configuration

The output of A/D scales, serial scales, or

iQUBE

systems can be configured to function as a total scale.

Once configured and calibrated, the total scale can be

used as a source for other system functions, including

streaming, setpoints, print formatting, and analog

output.
To set up a total scale from the indicator front panel,

use the scale configuration display (see Figure 3-2) to

select the A/D scales or

iQUBE

systems to configure

as a total scale. (Use the

Change Type

softkey to show

available A/D scales or

iQUBE

systems; use the right

navigation key to select the total scale sources.) In

Revolution

, assign the total scale to an unused

position then select source scales from the existing

A/D scales or

iQUBE

systems.