Setpoints

77

8.3

Batch Operations

Softkeys can be configured to allow operator control
of batch operations from the

820i

front panel (see

Figure 8-10), Softkeys can be configured using

Revolution

, serial commands, or the FEATURE menu

(see Section 3.2.3 on page 35).

Figure 8-10. Batching Softkeys

Setpoint

Display or change assigned setpoints.

Batch Start

Starts batch process.

Batch Pause

Pauses an active batch and turns off
a l l d i g i t a l o u t p u t s e x c e p t t h o s e
associated with concurrent and timer
setpoints. Processing is suspended
until

Batch Start

is pressed again.

Pressing

Batch Start

resumes the

batch and re-energizes all digital
outputs turned off by the

Batch Pause.

Batch Reset

Stops and resets an active batch to the
beginning of the process.

Batch Stop

Stops an active batch and turns off all
associated digital outputs.

To prevent personal injury and equipment
damage, software-based interrupts must
always be supplemented by emergency stop
switches and other safety devices necessary
for the application.

Batching Switch

The batching switch option, PN 19369, comes as a
complete unit in an FRP enclosure, with legend plate,
locking stop switch (mushroom button), and a run/
start/abort 3-way switch.

Both switches are wired into the indicator’s digital I/O
terminal strip as shown in Figure 8-12. Each switch
uses a separate digital input.

Once cables and switches have been connected to the
indicator, use the setup switch to place the indicator in
setup mode. Use the DIG I/O menu (see Section 3.2.7
on page 44) to configure
digital input and output
functions.

Figure 8-11. Batching Switch

When configuration is complete, exit setup mode.
Initialize the batch by turning the 3-way switch to

ABORT

, then unlock the STOP button (the STOP

button must be in the OUT position to allow the batch
process to run). The batching switch is now ready to
use.

If no digital input is assigned to BATRUN,
batching proceeds as if BATRUN were
always on: the batch will start when the
3-way switch is turned to RUN, but the
STOP mushroom button will not function.

Figure 8-12. Batching Switch Wiring Diagram Example

05/26/2006

11:08PM

2501

Scale

#1

lb

Gross

Setpoint Batch Start Batch Pause Batch Reset Batch Stop

Warning

Warning

RED

WHITE

BLACK

RED

BLACK

STOP/START MUSHROOM SWITCH

ABORT/RUN/START SWITCH

A
B
O
R
T

S
T
A
R
T

NO NC NC

NO NO

J5

+5VDC

GND

DIO1

DIO2

DIO3

DIO4

DIGITAL I/O

CPU BOARD

1 2 3 4 5 6 7 8 9 10

DIO5

DIO6

DIO7

DIO8

1

2

1

2

3

4

3

4

3

4