1 operating modes, 2 indicator operations, Operating modes – Rice Lake 820i Programmable Indicator/Controller - Installation Manual User Manual

Page 7: Indicator operations

Advertising
background image

Introduction

3

Front Panel

The

820i

front panel, shown in Figure 1-1, consists of

a 28-button keypad with a large backlit LCD display.

The keys are grouped as five configurable softkeys,

five primary scale function keys, four navigation keys,

and numeric entry keys.
Weight information is displayed with a graphical scale

in two font sizes. Status areas on the display are used

for operator prompts and entering data.
LCD display contrast and backlighting can be

adjusted using the

Display

button on the front panel.

Display

05/28/2006

12:57PM

Accept

CONTRAST

PFORMT

FEATURE

0

Adjust Screen Contrast

Default Backlite

On

Contrast (0-127) =>

Backlite Off

Figure 1-1. 820i Front Panel

Enclosures

The

820i

is available in universal (tilt-stand) and panel

mount enclosures. Stainless steel enclosures are rated

for NEMA 4X/IP66. This manual provides assembly

drawings and replacement parts lists for the universal

model; supplemental documentation provides

information specific to the panel mount model

(Section

1.4 on page

4).

1.1

Operating Modes

The

820i

has two modes of operation:

Normal mode

Normal mode is the weighing mode of the indicator.

The indicator displays gross, net, or tare weights as

required, using the secondary display to indicate scale

status and the type of weight value displayed. Once

configuration is complete and a legal seal is affixed to

the large fillister-head screw on the indicator

enclosure, this is the only mode in which the

820i

can

operate.

Setup mode

Most of the procedures described in this manual

require the indicator to be in setup mode, including

configuration and calibration.
To enter setup mode, remove the large fillister head

screw from the enclosure. Insert a screwdriver or a

similar tool into the access hole and press the setup

switch once. The indicator display changes to show

scale configuration menus.

1.2

Indicator Operations

Basic

820i

operations are summarized below:

Toggle Gross/Net Mode

Press the

GROSS/NET

key to switch the display mode

from gross to net, or from net to gross. If a tare value

has been entered or acquired, the net value is the gross

weight minus the tare. If no tare has been entered or

acquired, the display remains in gross mode.
Gross mode is indicated by the word

Gross

(or

Brutto

in

OIML mode); net mode is indicated by the word

Net

.

To display audit trail information, press and hold the

Gross/Net

mode key for three seconds. Weighing

functions continue while audit trail information is

displayed. Press the

Gross/Net

or

CLR

key to exit the

audit trail display.

Toggle Units

Press the

UNITS

key to switch between primary,

secondary, and tertiary units.

Zero Scale

1. In gross mode, remove all weight from the scale

and wait for the standstill annunciator (

).

2. Press the

ZERO

key. The center of zero (

)

annunciator lights to indicate the scale is zeroed.

Acquire Tare

1. Place container on scale and wait for the

standstill annunciator (

).

2. Press the

TARE

key to acquire the tare weight of

the container.

3. Display shifts to net weight and shows the word

Net

on the display.

Remove Stored Tare Value

1. Remove all weight from the scale and wait for

the standstill annunciator (

).

2. Press the

TARE

key (or, in OIML mode, the

ZERO

key). Display shifts to gross weight and

shows the word

Gross

.

Print Ticket

1. Wait for the standstill annunciator (

).

2. Press the

PRINT

key to send data to the serial

port.

Accumulator Functions

The accumulator must be enabled before use in either

normal mode or setpoint operations. Once enabled,

weight (net weight if a tare is in the system) is

accumulated whenever a print operation is performed

using the

PRINT

key, digital input, or serial command.

The scale must return to zero (net zero if a tare is in

the system) before the next accumulation.
The

Display Accum

softkey can be configured to

display the current accumulator value. Printing while

the accumulator is displayed, or when the setpoint

PSHACCUM function is active, uses the ACCFMT

print format (see Section

6.0 on page

54).

Press the

CLEAR

key twice to clear the accumulator.