Rice Lake 820i Programmable Indicator/Controller - Installation Manual User Manual

Page 85

Advertising
background image

Serial Commands

81

SC.DFSENS#n

Digital filter cutout sensitivity

2OUT, 4OUT, 8OUT, 16OUT, 32OUT, 64OUT, 128OUT

SC.DFTHRH#n

Digital filter cutout threshold

NONE, 2D, 5D, 10D, 20D, 50D, 100D, 200D, 250D

SC.RATLTRAP#n

Rattletrap filtering

OFF, ON

SC.SMPRAT#n

Sample rate

30HZ, 60HZ, 120HZ, 240HZ, 480HZ, 960HZ

SC.PWRUPMD#n

Power up mode

GO, DELAY

SC.TAREFN#n

Tare function

BOTH, NOTARE, PBTARE, KEYED

SC.PRI.DECPNT#n

Primary units decimal position

8.888888, 88.88888, 888.8888, 8888.888, 88888.88,
888888.8, 8888888, 8888880, 8888800

SC.PRI.DSPDIV#n

Primary units display divisions

1D, 2D, 5D

SC.PRI.UNITS#n

Primary units

lb, kg, g, oz, tn, t, gn, troyoz, troylb, lt, CUSTOM, NONE, OFF

SC.PRI.CUNITS#n

Primary custom units

Specify units if SC.PRI.UNITS=CUSTOM

SC.SEC.DECPNT#n

Secondary units decimal position

8.888888, 88.88888, 888.8888, 8888.888, 88888.88,
888888.8, 8888888, 8888880, 8888800

SC.SEC.DSPDIV#n

Secondary units display divisions

1D, 2D, 5D

SC.SEC.UNITS#n

Secondary units

lb, kg, g, oz, tn, t, gn, troyoz, troylb, lt, CUSTOM, NONE,
OFF

SC.SEC.CUNITS#n

Secondary custom units

Specify units if SC.SEC.UNITS=CUSTOM

SC.SEC.MULT#n

Secondary units multiplier

0.00000–9999999

SC.TER.UNITS#n

Tertiary units

lb, kg, g, oz, tn, t, gn, troyoz, troylb, lt, CUSTOM, NONE,
OFF

SC.TER.CUNITS#n

Tertiary custom units

Specify units if SC.TER.UNITS=CUSTOM

SC.TER.DECPNT#n

Tertiary units decimal position

8.888888, 88.88888, 888.8888, 8888.888, 88888.88,
888888.8, 8888888, 8888880, 8888800

SC.TER.DSPDIV#n

Tertiary units display divisions

1D, 2D, 5D

SC.TER.MULT#n

Tertiary units multiplier

0.000001–9999999

SC.ROC.DECPNT#n

Tertiary units decimal position

8.888888, 88.88888, 888.8888, 8888.888, 88888.88,
888888.8, 8888888, 8888880, 8888800

SC.ROC.DSPDIV#n

Rate-of-change units display divisions

1D, 2D, 5D

SC.ROC.MULT#n

Rate-of-change units multiplier

0.000001–9999999

SC.ROC.UNITS#n

Rate-of-change units

SEC, MIN, HOUR

SC.ROC.INTERVL#n

Rate-of-change interval

1–100

SC.ROC.REFRESH#n

Rate-of-change refresh interval

0.1–60

SC.RANGE1.MAX#n

Weight maximum for first range or
interval

weight

SC.RANGE2.MAX#n

Weight maximum for second range or
interval

weight

SC.RANGE3.MAX#n

Weight maximum for third range or
interval

weight

SC.ACCUM#n

Accumulator enable

ON, OFF

SC.VISIBLE#n

Scale visibility

ON, OFF

SC.PEAKHOLD#n

Peak hold

OFF, NORMAL, BI-DIR, AUTO

SC.WZERO#n

Zero calibration

SC.WVAL#n

Test weight value

test_weight_value

SC.WSPAN#n

Span calibration

SC.WLIN.F1#n
SC.WLIN.F5#n

Actual raw count value for linearization
points 1–5

0–16777215

Command

Description

Values

Table 9-3. SCALES Serial Commands (Continued)