To begin a batch process, turn the 3-way switch to

START

momentarily. If the STOP button is pushed

during the batch process, the process halts and the

button locks in the IN position.
The

START

switch is ignored while the STOP button is

locked in the IN position. The STOP button must be

turned counterclockwise to unlock it, then released

into the OUT position to enable the 3-way switch.
To restart an interrupted batch from the step where it

left off, do the following:

1. Unlock STOP button (OUT position)
2. Turn 3-way switch to

START

To restart an interrupted batch from the first batch

step, do the following:

1. Turn 3-way switch to

ABORT

2. Unlock STOP button (OUT position)
3. Turn 3-way switch to

START

Note

Use this procedure (or the BATRESET

serial command) to initialize the new batch

routine following any change to the

setpoint configuration.