To begin a batch process, turn the 3-way switch to
START
momentarily. If the STOP button is pushed
during the batch process, the process halts and the
button locks in the IN position.
The
START
switch is ignored while the STOP button is
locked in the IN position. The STOP button must be
turned counterclockwise to unlock it, then released
into the OUT position to enable the 3-way switch.
To restart an interrupted batch from the step where it
left off, do the following:
1. Unlock STOP button (OUT position)
2. Turn 3-way switch to
START
To restart an interrupted batch from the first batch
step, do the following:
1. Turn 3-way switch to
ABORT
2. Unlock STOP button (OUT position)
3. Turn 3-way switch to
START
Note
Use this procedure (or the BATRESET
serial command) to initialize the new batch
routine following any change to the
setpoint configuration.