3.2

Cable Connections

The 920i indicator provides four cord grips and two MIL-C connectors for cabling into the indicator. The free cord
grips come with a plug installed to prevent moisture from entering the enclosure.

Figure 3-3 shows the assignments for the 920i cord grips.

MIL-C
power

Wireless LAN
- optional

To scanner -
optional

To wireless
transceiver

On/Off
power
toggle

Wired
version plug

Figure 3-3. 920i Cord Grip Assignments

3.3

Supplying Power to the Indicator From the Forklift Battery

CAUTION

The indicator power source will be connected directly from the battery of the forklift. Most
typical is 12 volts for propane, gas, and diesel forklifts. However, some diesel forklifts are 24
volts.

The CLS series cargo lift scale will not operate on a positive ground forklift. Verify the forklift has a
negative ground electrical system.

Refer to the forklift users manual to further verify grounding requirements.

There is a supplied on/off power toggle switch which manually cuts power from the battery of the forklift. This
way there won’t be any additional draw on the battery when the scale is not in use.

On/off toggle switch
location on 920i

Figure 3-4. Toggle Switch Location