9.0 Scanner Option
The CLS-920i, has an optional scanner system (Symbol
®
MS-320x semi-omnidirectional scan) which provides a
quick and easy integration into bar code scanning into all types of OEM devices. Figure 9-1 illustrates the scanner
used with CLS-920i (optional).
Figure 9-1. Bar Code Scanner
9.1
Mounting the Scanner
A special mounting plate comes with the scanner and can be mounted directly to the mounting bracket that holds
the 920i indicator to the forklift cage. Use the two screws provided to mount the plate either on the left or the right
side of the indicator.
Two holes are
p r o v i d e d o n
e a c h s i d e o f
the indicator
m o u n t i n g
bracket. The
s c a n n e r c a n
be installed on
either side.
Scanner
Figure 9-2. Mounted Scanner Plate
Once the mounting plate is attached, the scanner needs to be connected. To connect the scanner use the following
steps:
1. Plug the nine-pin D-connector into the miniscan scanner.
2. Run the other end of the scanner cable through the grommeted hole on the mounting bracket and down to
an available cord grip on the indicator.