2 serial command configuration, 3 front panel configuration, 4 total scale configuration – Rice Lake CLS-920i Cargo Lift Scale Installation Manual User Manual

Page 27: Serial command configuration, Front panel configuration, Total scale configuration

Advertising
background image

CLS-920i Installation Manual

23

4.1.2

Serial Command Configuration

The serial command set can be used to configure the

920i

indicator using either a personal computer,

terminal, or remote keyboard. Like

iRev

, serial

command configuration sends commands to the
indicator serial port; unlike

iRev

, serial commands can

be sent using any external device capable of sending
ASCII characters over a serial connection.

Serial commands duplicate the functions available
using the indicator front panel and provide some
functions not otherwise available. Serial commands
can be used to simulate pressing front panel keys, to
configure the indicator, or to dump lists of parameter
settings.

4.1.3

Front Panel Configuration

Use the CONFIG submenu under the SCALES menu
to configure A/D scales. For example, in an indicator
with a single-channel A/D card installed in Slot 1, the
Scale Configuration display will show the A/D listed
(

Slot 1 Channel 1

) under the

AVAILABLE A/D’s

column. Use

the

left

navigation key to select the A/D, then press the

center softkey,

Add

. The A/D is then moved to the

Associated A/D’s column. If no other A/D’s are listed
in the

AVAILABLE A/D’s

column, the center softkey

changes to

Done

, as shown in Figure 4-2. Press

Done

to

exit the Scale Configuration display..

Figure 4-2. Scale Configuration Display

4.1.4

Total Scale Configuration

The output of two or more A/D scales or

iQUBE

systems can be configured to function as a total scale.
Once configured and calibrated, the total scale can be
sued as a source for other system functions, including
streaming, setpoints, print formatting, and analog
output.

To set up a total scale from the indicator front panel,
use the scale configuration display (see Figure 4-2) to
select the A/D scales or

iQUBE

systems to configure as

a total scale. (Use the

Change Type

softkey to show

available A/D scales or

iQUBE

systems; use the right

navigation key to select the total scale sources.) In

iRev

, assign the total scale to an unused position then

select source scales from the existing A/D scales or

iQUBE

systems.

The FORMAT configuration of the total scale (see
Figure 4-5 on page 28) should match that of the source
scales. However, the value specified for the total scale
GRADS parameter should be specified as the sum of
the GRADS values for the source scales. For example:
if SCALE 1 is set to GRADS=10000, SCALE 2 to
GRADS=5000, SCALE 3 (the total scale) should be set
to 15000 grads.

The total scale will show an overrange indication if the
maximum capacity of any source scale is exceeded,
and show dashes if any source scale reads a negative
value. Source scales will respond to Tare and Zero
operations performed on the total scale.