Rice Lake CLS-920i Cargo Lift Scale Installation Manual User Manual
Page 19
CLS-920i Installation Manual
14
The indicator draws its power from the forklift battery. After the indicator is mounted, run the power cable along
the forklift chassis down to the forklift battery.
Run power cable along
chassis to the forklift
scale battery
Figure 3-5. Run Power Cable to the Forklift Battery
Note
DO NOT plug in the power connector into the bottom of the indicator until power hookup is completed.
A supplied in-line fuse is also included with the CLS-series cargo lift scale. The fuse comes enclosed in an in-line
fuse holder (shown in Figure 3-6) and is attached where the stripped termination of the wires is located.
Replacement of the in-line fuse is described in the CLS-series Service manual if needed.
Figure 3-6. Inline Fuse
Attach the three stripped wires to the forklift battery using the following wire code.
Table 3-1. Power Hookups to Forklift Battery
Wire Color
Signal
Red
Positive on Battery
Black
Negative on Battery
Blue
Ground/Chassis
Note
Supplied termination hardware includes (3) 1/4" eyelits for 1/4" bolts..