1 lithium-ion battery specifications, 2 general precautions, Lithium-ion battery specifications – Rice Lake CLS-920i Cargo Lift Scale Installation Manual User Manual

Page 21: General precautions

Advertising
background image

CLS-920i Installation Manual

16

3.5

Supplying Power to the Two-Channel iQube Using a Lithium-Ion Battery

If using a wireless version of the CLS-920i, the CLS scale uses a supplied lithium-ion battery to supply power to
the two-channel iQube. The wireless version of the CLS-920i does not come with a coiled cable. The lithium-ion
battery is located on the top of the cover plate in a painted enclosure.

Figure 3-9. Lithium-Ion Battery Location

3.5.1

Lithium-Ion Battery Specifications

Table 3-2. Battery Specifications

Nominal Capacity

6600 mAh

Nominal Voltage

11.1 V

Charging Method

Constant Current

Constant Voltage

Charging Voltage

12.6 V

Charging Current

4.0 A

Charging Time

100% @ 8 hours

Ambient Temperature

Charge

0

°

- +40

°

C

Discharge

-20

°

- +60

°

C

Storage

-20

°

- +50

°

C

Weight (Maximum)

430 g

Dimensions (Maximum)

Depth

22.80 mm

Length

214.0 mm

Volumetric Energy Density

466 Wh/I

Gravimetric Energy Density

167 Wh/kg

Maximum Hours of Charge

24 Hours

Nominal Capacity

6600 mAh

3.5.2

General Precautions

There are some precautions that should be taken when handling lithium-ion batteries.

Handling

• Do not short circuit

• Do not immerse in water

• Do not disassemble or deform battery

• Keep away from excessive heat (+100

°

C) or dispose of battery in fire

• Avoid excessive physical shock or vibration

• Keep out of reach of children