4.2.7
Analog Output Menu
The ALGOUT menu is shown only if the analog output option is installed. If the analog output option is installed,
configure all other indicator functions and calibrate the indicator itself before configuring the analog output. See
the Analog Output Card Installation Instructions, PN 69089, for more information.
4$"-&4
4&3*"-
'&"563&
1'03.5
4&5154
%*(*0
"-(065
7&34
OVNCFS
OVNCFS
4063$&
130(
0''4&5
&33"$5
4$"-&O
'6--4$
)0-%
;&304$
.*/
OVNCFS
."9
OVNCFS
58;&30
5841"/
.0%&
(3044
/&5
*G4063$&ò130(
Figure 4-16. Analog Output Menu
Table 4-10. Analog Output Menu Parameters
ALG OUT Menu
Parameter
Choices
Description
Level 2 submenus
SOURCE1
PROG
SCALEn
Specifies the scale tracked by the analog output. PROG indicates that the analog output is under
program control.
MODE1
GROSS
NET
Specifies the weight data, gross or net, tracked by the analog output.
OFFSET
0%
20%
Zero offset. Select 0% for 0–10 V or 0–20 mA output; select 20% for 4–20 mA output. This
parameter must be set before calibrating the analog output.
ERRACT
FULLSC
HOLD
ZEROSC
Error action. Specifies how the analog output responds to system error conditions.
Possible values are:
FULLSC: Set to full value (10 V or 20 mA)
HOLD: Hold current value
ZEROSC: Set to zero value (0 V or 4 mA)
MIN
000000
0–9999999
Specifies the minimum weight value tracked by the analog output. Specify a value in the range
0–9999999.
MAX
10000
0–9999999
Specifies the maximum weight value tracked by the analog output. Specify a value in the range
0–9999999
TWZERO
40
0–65535
Tweak zero. Enter tweak value to adjust the analog output zero calibration. Use a multimeter to
monitor the analog output value.
TWSPAN
59650
0-65535
Tweak span. Enter tweak value to adjust the analog output span calibration. Use a multimeter to
monitor the analog output value.