Rice Lake CLS-920i Cargo Lift Scale Installation Manual User Manual

Page 59

Advertising
background image

CLS-920i Installation Manual

55

Parent List

Parameter Name Default Value

Min

Max

Type

Description

App
Parameters

Zero Tolerance
Weight

5

1

1000

Integer

This is the maximum weight that the forklift
scale must return to between lifting and
weighing skids. If the weight doesn’t fall
below this weight after weighing and
removing a skid from the forks, another
weighment is not allowed. If the message,
Scale must zero between skids, then the
operator must lower the skid if one is on the
forks. If the weight doesn’t fall below the Zero
Tolerance Weight with the forks empty, zero
the scale with the ZERO key on the 920i.

Show Pitch &
Roll

None

Yes/No

During the initial installation and setup, it
might be adventageous to see the pitch and
roll information. Set this value to YES to have
the 920i show the pitch and roll data on the
main screen.

Minimum PRO
Length

9

1

20

Integer

The program needs to be able to identify and
validate an entered or scanned data as a
PRO number. Set this value to the minimum
length of a valid PRO number.

Maximum PRO
Length

9

1

20

Integer

Set this value to the maximum length of a
valid PRO number.

Alpha
Characters in
PRO

None

Yes/No

Some PROs are numeric only, other may
have letters in the string. Set this value to YES
if the entered or scanned PRO string will
contain numbers and letters.

Scanner Begin
Token (ASCII
Value)

2

1

127

Character

The scanner data must be wrapped with a
start character and an end character for the
920i to recognize it. The default is an ASCII 2
(STX) and the scanner must be configured to
send this character. If for some reason, the
scanner you are using cannot send a STX,
you may set this value to the ASCII value of
the starting character the scanner will be
sending.

Scanner End
Token (ASCII
Value)

3

1

127

Character

The default is an ASCII 3 (ETX) and the
scanner must be configured to send this
character. If for some reason, the scanner
you are using cannot send an ETX, you may
set this value to the ASCII value of the ending
character the scanner will be sending.

Battery Life
Offset (Hrs)

0

0

48

Integer

If a battery has been properly calibrated or
the life is not linear, it may be necessary to
add an offset to the displayed battery life. If
the battery life seems to show plenty of life
and then quickly fails to no life at 8 hours for
example, then enter 8.0 for this setting. This
should correct the displayed battery life to
represent the true hours remaining.

Table 5-1. Supervisor List Parameters