3 operating modes, 4 indicator operations, Operating modes – Rice Lake CLS-920i Cargo Lift Scale Installation Manual User Manual

Page 9: Indicator operations

Advertising
background image

CLS-920i Installation Manual

5

1.3.3

Operating Modes

The

920i

has two modes of operation:

Normal mode

Normal mode is the weighing mode of the indicator. The indicator displays gross, net, or tare weights as
required, using the secondary display to indicate scale status and the type of weight value displayed. Once
configuration is complete and a legal seal is affixed to the large fillister-head screw on the indicator enclosure,
this is the only mode in which the

920i

can operate.

Setup mode

Most of the procedures described in this manual require the indicator to be in setup mode, including
configuration and calibration.

To enter setup mode, remove the large fillister head screw from the enclosure. Insert a screwdriver or a similar
tool into the access hole and press the setup switch once. The indicator display changes to show scale
configuration menus.

1.3.4

Indicator Operations

Basic

920i

operations are summarized below:

Toggle Gross/Net Mode

Press the

GROSS/NET

key to switch the display mode from gross to net, or from net to gross. If a tare value has been

entered or acquired, the net value is the gross weight minus the tare. If no tare has been entered or acquired, the
display remains in gross mode.

Gross mode is indicated by the word

Gross

(or

Brutto

in OIML mode); net mode is indicated by the word

Net

.

Toggle Units

Press the

UNITS

key to switch between primary, secondary, and tertiary units.

Zero Scale

1. In gross mode, remove all weight from the scale and wait for the standstill annunciator (

).

2. Press the

ZERO

key. The center of zero (

) annunciator lights to indicate the scale is zeroed.

Acquire Tare

1. Place container on scale and wait for the standstill annunciator (

).

2. Press the

TARE

key to acquire the tare weight of the container.

3. Display shifts to net weight and shows the word

Net

on the display.

Remove Stored Tare Value

1. Remove all weight from the scale and wait for the standstill annunciator (

).

2. Press the

TARE

key (or, in OIML mode, the

ZERO

key). Display shifts to gross weight and shows the word

Gross

.

Print Ticket

1. Wait for the standstill annunciator (

).

2. Press the

PRINT

key to send data to the serial port.

Accumulator Functions

The accumulator must be enabled before use in either normal mode or setpoint operations. Once enabled, weight
(net weight if a tare is in the system) is accumulated whenever a print operation is performed using the

PRINT

key,

digital input, or serial command. The scale must return to zero (net zero if a tare is in the system) before the next
accumulation.

The

Display Accum

softkey can be configured to display the current accumulator value. Printing while the

accumulator is displayed, or when the setpoint PSHACCUM function is active, uses the ACCFMT print format

Press the

CLEAR

key twice to clear the accumulator.

Advertising