CLS-920i Installation Manual

4.0 Configuration of Scale Parameters

Note

While the fuctionality remains the same for a standard 920i HMI indicator, there are certain menu choices that
need to be changed in the User Configuration section of this manual specific to the proper functioning of the
CLS-Series Cargo Lift Scale.

To configure the

920i

indicator, the indicator must be

placed in setup mode. The setup switch is accessed by
removing the large fillister head screw on the backplate
of the universal and deep enclosures. Switch position is
changed by inserting a screwdriver into the access hole
and pressing the switch.

When the indicator is placed in setup mode, a series of
menus is shown across the top of the display, along
with the words

Scale Configuration

. The SCALES menu

is highlighted as the first used to configure the
indicator. Detailed descriptions of these menus are
provided in Section 4.2.

When configuration is complete, press the

Exit

or

Save

and Exit

softkey to exit setup mode, then replace the

setup switch access screw.

The

Exit

softkey exits setup mode without saving

parameter changes to NV RAM. Changes made
to the configuration remain in the system until
indicator power is cycled.

Save and Exit

writes all parameter changes to NV

RAM before returning to normal mode.

4.1

Configuration Methods

The

920i

indicator can be configured by using the front

panel keys to navigate through a series of configuration
menus or by sending commands or configuration data
to an indicator serial port. Configuration using the
menus is described in Section 4.1.3.

C o n f i g u r a t i o n u s i n g t h e s e r i a l p o r t c a n b e
accomplished using either the serial command set or
the

iRev

configuration utility.

Note

Some configuration parameters, such as those
used to configure the

920i

display and widgets,

cannot be accessed through the configuration
menus.

iRev

provides the most complete and

efficient configuration interface for the

920i

.

4.1.1

iRev Configuration

The

iRev

configuration utility provides the preferred

method for configuring the

920i

indicator.

iRev

runs on

a personal computer to set configuration parameters for
the indicator. When

iRev

configuration is complete,

configuration data is downloaded to the indicator.

Note

All configuration parameters can be set up
using iRev except configuration parameters
associated with the iQube. Those parameters
must be set up manually which is explained in
further detail in Section 4.2.2.

iRev

supports both uploading and downloading of

indicator configuration data. This capability allows
configuration data to be retrieved from one indicator,
edited, then downloaded to another indicator with an
identical hardware configuration.

Figure 4-1. iRev Hardware Configuration Display

To use

iRev

, do the following:

1. Install

iRev

on an IBM-compatible personal

computer. See Section 5.0 on page 50 for
detailed hardware and software requirements.

2. With both indicator and PC powered off,

connect the PC serial port to the RS-232 pins
on the indicator serial port.

3. Power up the PC and the indicator. Use the

setup switch to place the indicator in setup
mode.

4. Start the

iRev

program.

iRev

provides online help for each of its configuration

displays. Parameter descriptions provided in this manual
for front panel configuration can also be used when
configuring the indicator using

iRev

: The interface is

different, but the parameters set are the same.

See Section 6.4 for more information about using

iRev

to

configure the

920i

.