Rice Lake CLS-920i Cargo Lift Scale Installation Manual User Manual

Page 63

Advertising
background image

CLS-920i Installation Manual

60

12. The indicator will then prompt

Cal-Match Point 1

. Carefully place the test weight on the left tine (from the

forklift operator’s point of view).

&/2+,)&4
,//+).'

,%&4

With the weight in place, press the

Enter

key.

13. The indicator will then prompt

Cal-Match Point 2

. Remove the weight from the left tine and place it on the

right tine (you must use exactly the same test weight). When ready, press the

Enter

key.

14. The calibration will finalize. When done, press the

Save and Exit

softkey.

15. Calibration can be verified by placing the test weight on either tine - the reading must be the same.