TOSHIBA

TMP87PP24A

(2) High-Speed Programming Operation (Торг = 25 ± 5°C)

Parameter

Symbol

Conditions

Min

Typ.

Max

Unit

Input High Voltage

V|H4

Vcc

X

0.7

-

Vcc

V

Input Low Voltage

V|L4

0

-

Vccx0.12

Power Supply Voltage

Vcc

6.0

6.25

6.5

Program Power Supply Voltage

Vpp

12.5

12.75

13.0

Initial Program Pulse Width

tpw

Vcc = 6.0 V

0.095

0.1

0.105

ms

AO toA16

CE

OE

PGM

Vpp

X

X

D7toD0 Unknown

N._______ /

Input data

>

7

write

X

/

Data outputs ^

Verify

Note 1: When Vcc power supply is turned on or after, Vpp must be increased.

When Vcc power supply is turned off or before, Vpp must be increased.

Note 2: The device must not be set to the EPROM programmer or picked op from it under applying the

program voltage (12.5 V ± 0.5 V =V) to the Vpp pin as the device is damaged.

Note 3: Be sure to execute the recommended programing mode with the recommended programing

adaptor. If a mode or an adaptor except the above, the misoperation sometimes occurs.