TOSHIBA

TMP87CM24A/P24A

SCK pin

SlOF

SO pin Bite

X

Bit?

tsoDH =min 3.5/fc [s] (In the NORMAL1/2, IDLE1/2 modes)

= min 3.5/fs [s] (In the SLOW, SLEEP modes)

Figure 2-39. Transmitted Data Hold Time at End of Transmit

(2) 4-Bit and 8-Bit Receive

Modes

After

setting

the

control

registers

to

the

receive

mode,

set

SIOS

to

"1"

to

enable

receiving.

The

data

are then transferred to the shift register via the SI pin in synchronous with the serial clock. When one

word

of

data

has

been

received,

it

is

transferred

from

the

shift

register

to

the

data

buffer

register

(DBR).

When

the

number

of

words

specified

with

the

BUF

has

been

received,

an

INTSIO

(buffer

full)

interrupt

is

generated

to

request

that

these

data

be

read

out.

The

data

are

then

read

from

the

data

buffer registers by the interrupt service program.

When

the

internal

clock

is

used,

and

the

previous

data

are

not

read

from

the

data

buffer

register

before

the

next

data

are

received,

the

serial

clock

will

stop

and

an

automatic-wait

will

be

initiated

until the data are read. A wait will not be initiated if even one data word has been read.

Note:

Waits are also canceled by reading a DBR not being used as a received data buffer register

is read; therefore, during SIO do not use such DBR for other applications.

When

an

external

clock

is

used,

the

shift

operation

is

synchronized

with

the

external

clock;

therefore,

the

previous

data

are

read

before

the

next

data

are

transferred

to

the

data

buffer

register.

If

the

previous

data

have

not

been

read,

the

next

data

will

not

be

transferred

to

the

data

buffer

register

and

the

receiving

of

any

more

data

will

be

canceled.

When

an

external

clock

is

used,

the

maximum

transfer

speed

is

determined

by

the

delay

between

the

time

when

the

interrupt

request is generated and when the data received have been read.

The

receiving

is

ended

by

clearing

SIOS

to

"0"

or

setting

SIOINH

to

"1"

in

buffer

full

interrupt service

program. When SIOINH is set, the receiving is immediately ended and SlOF is cleared to "0".

When

SIOS

is

cleared,

the

current

data

are

transferred

to

the

buffer

in

4-bit

or

8

-bit

blocks.

The

receiving

mode

ends

when

the

transfer

is

completed.

SlOF

is

cleared

to

"0"

when

receiving

is

ended

and thus can be sensed by program to confirm that receiving has ended.

If

it

is

necessary

to

change

the

number

of

words

in

external

clock

operation,

SIOS

should

be

cleared

to "0" then BUF must be rewritten after confirming that SlOF has been cleared to "0".

If

it

is

necessary

to

change

the

number

of

words

in

internal

clock,

during

automatic-wait

operation

which

occurs

after

completion

of

data

receive,

BUF

must

be

rewritten

before

the

received

data

is

read out.

Note:

The buffer contents are lost when the transfer mode is switched. If it should become

necessary to switch the transfer mode, end receiving by clearing SIOS to "0", read the last

data and then switch the transfer mode.