Pulse width modulation (PWM) output mode

PWM

output

with

a

resolution

of

8

-bits

is

possible.

The

internal

clock

is

used

for

counting

up.

The

contents

of

the

TREG5

is

compared

with

the

contents

of

the

up-counter.

If

a

match

is

found,

the

timer

F/F5

output

is

toggled.

The

counter

continues

counting

and,

when

an

overflow

occurs,

the

timer

F/F5

is

again

toggled

and

the

counter

is

cleared.

The

timer

F/F5

output

is

inverted

and

output

to the PWM (P41) pin. In the case of PWM output, set the P41 output latch to "1" and configure as

an output with P4CR1. An INTTC5 interrupt is generated when an overflow occurs.

TREG5

is

configured

a

2-

stage

shift

register

and,

during

output,

will

not

switch

until

one

output

cycle

is

completed

even

if

TREG5

is

overwritten;

therefore,

output

can

be

altered

continuously.

Also,

the

first time, TREG5 is shifted by setting TC5S (bit 5 in TC5CR) to "1" after data are loaded toTREGS.

Note : PWM output mode can be used in only NORMAL 1/2 or IDLE 1/2 mode.

Internal clock

PWM pin

INTTC5 interrupt

1

cycle

Figure 2-32. PWM Output Mode Timing Chart

Table 2-7. PWM Output Mode

Source clock

Resolution

Repeat cycle

NORMAL1/2, DLE1/2mode

At fc = 8MHz

At fc = 4.194304 MHz

At fc = 8MHz

At fc = 4.194304 MHz

DV7CK = 0

DV7CK= 1

fc/2^ [Hz]

500 [ns]

953.7 [ns]

128 [/.s]

244 [//s]

fc/2

250 [ns]

476.8 [ns]

64 [//s]

122

[^s]

fc

125 [ns]

238.4 [ns]

32

[^s]

61

i^s]

3

-

24-81

2002

-

10-03