TOSHIBA

TMP87CM24A/P24A

2.10.2

Control

The

LCD

driver

is

controlled

using

the

LCD

control

register

(LCDCR).

The

LCD

driver's

display

is

enabled

using

the

EDSP.

Immediately

after

return

from

reset

or

standby,

it

takes

maximum

1

s

(Торг

=-10

°C)

(fc =

8

MHz, SLFR

:00

h

)

for the LCD driver's booster circuit to boost up to the specified voltage. If the

display

is

enabled

before

the

specified

voltage

is

reached,

the

voltage

may

not

be

boosted

properly

due to load on the SEG/COM.

7

6 5

4 3 2

1 0

EDSP

SLfR

____ ________ ___ _____

(Initial value : 0000 0000)

LCDCR

(

0028

h

)

SLF

Selection of LCD
frame frequency

00 : fc/2^^ or fs/2^ [Hz]
01 : fc/2^^ or fs/2^

10 : fc/2^5
11 : fc/2^3

DUTY

Selection of
driving methods

000:1/4 Duty (1/3 Bias)
001:1/3 Duty (1/3 Bias)
010: Reserved
011:1/2 Duty (1/3 Bias)

100: Static
101: Reserved
11*: Reserved

Write

only

SLFR

Selection of boost
frequency

00 : fc/2^3 or fs/2^ [Hz]
01 : fc/2" or fs/2^

10 : fc/2^° or fs/2^
11 : fc/29

EDP

LCD Display Control

0 : Blanking

1 : Enables LCD display (Blanking is released)

Note 1:

fc: High-frequency clock, fs: Low-frequency clock

Note 2:

The LCDCR is a write-only register. It can not be operated by the read-modify-write

instruction (Bit manipulation instructions of SET, CLR, etc. and Arithmetic

instructions of AND, OR, etc.)

Figure 2-44. LCD Driver Control Register

3

-

24-92

2002

-

10-03