TOSHIBA

TMP87CM24A/P24A

Note

6:

Change

EINTCR

only

when

IMF

=

0.

After

changing

EINTCR,

interrupt

latches

of

external

interrupt inputs must be cleared to "0" using load instruction.

Example : Changes INT2 edge selection from rising edge to falling edge

Dl

; IMF <-0 (disables interrupt service)

LD

(EINTCR), 10000110B

; INT2ES ^ 1 (changes edge selection)

LD

(ILL),01111111B

; IL7 ^ 0 (dears interrupt latch)

El

; IMF <-1 (enables interrupt service)

Note?:

if

changing

the

contents

of

INT1ES

during

NORMAL1/2

mode,

interrupt

latch

of

external

interrupt input INTI must be cleared after 14 machine cycles (when INT1NC =1) or 50 machine

cycles (when INT1NC = 0) from the time of changing. During SLOW mode, 3 machine cycles are

required.

Note 8: In order to change of external interrupt input by rewriting the contents of INT2ES and INT3ES

during

NORMAL1/2

mode,

clear

interrupt latches

of external interrupt

inputs

(INT2

and

INT3)

after 8 machine cycles from the time of rewriting. During SLOW mode, 3 machine cycles are

required.

Note 9: In order to change an edge of timer counter input by rewriting the contents of INT2ES and

INT3ES during NORMAL 1/2 mode, rewrite the contents after timer counter is stopped (TC*s = 0),

that is, interrupt disable state. Then, clear interrupt laches of external interrupt inputs (INT2

and INT3) after 8 machine cycles from the time of rewriting to change to interrupt enable state.

Finally, start timer counter. During SLOW mode, 3 machine cycles are required.

Example : When changing TCI pin inputs edge in external trigger timer mode from rising edge to

falling edge.

8

-machine

cycles

I

LD(TC1CR),01001000B

Dl

LD (EINTCR),00000100B

NOP

to

NOP

LD (ILL),01111111B

El

LD(TC1CR),01111000B

T C I 0 0 (stop TCI)

IMF

0

(disable

interrupt

service)

INT2ES <- 1 (change edge selection)

IL7 <-0 (clear interrupt latch)

IMF

1

(enable

interrupt

service)

TCIS^II (startTCI)

Note 10:

When high-impedance is specified for port output in stop mode, port input is forcibly fixed

to

low

level

internally.

Thus,

interrupt

latches

of

external

interrupt

inputs

except

I

NTS

(P20/STOP) which are also used as ports may be set to "1". To specify high-impedance for

port output in stop mode, first disable interrupt service (IMF = 0), activate stop mode. After

releasing

stop

mode,

clear

interrupt

latches

using

load

instruction,

then,

enable

interrupt

service.

Example : Activating stop mode

LD (SYSCR1),01000000B

Dl

SET

LDW

El

(SYSCRI).STOP

(IL), 1111011101010111B

OUTEN

<-

0

(specifies

high-impedance)

IMF <- 0 (disables interrupt service)

STOP <- 1 (activates stop mode)

IL11,7,

5,

3

<-0

(clears

interrupt

latches)

IMF <- 1 (enables interrupt service)