TOSHIBA

6 F 8 A 0 7 7 4 ,

I To chiingo the mdiciitiag unit (2):

Only in case of the convcacc lor special specifications (refer to 7,33 ^‘Converter for

Special specificaiions’'), Code of vciumctric flow direction F(fi>ced forward flow),

R(fixed reverse flow'), B(auiomatic selection bi-directional flow) can be selected,

In case of normal converter* the code of volumetric flow direction does not appear.

The following example shows how to change the primary indicating unit from F to K,

Key operation

Display example

Description

Sb'l

Bl: UNIT 1

F

Press [SET] first to start the items selection sequence

to select Bl: UNIT I from among the configuration
items using ( ► ] and [

a

] keys

1

hen press [Sbri ]

again to display the current primary indicating unit (ni^
F in this example).

Bl: UNIT 1

m* F

Pressing [ ► ], the cursor appears.

Bl: UNIT 1

Pressing [ ► ], the cursor moves to the second unit

I_ _ 1

m

’ _ F

(time unit) of primary indicating unit.

Pressing 1 ► ], the cursor moves to the third unit

Bl: UNIT 1

r

(code of volumetric flow direction) of primary

HI r

indicating unit.

Select “R’' as the third unit (code of volumetric flow

Bl: UNIT 1

direction) of primary indicating unit by pressing [,^)

m' R

as many times as necessary', (Note 1)

SE'T

Bl ■ UNIT 1

Pressing ÍSE T), the cursor disappears and the changed

n* R

display dickers. Press [SE%T ] again

t o

save the unit.

SCI'

Bl: UNIT 1

Pressing |SET], the system returns to the item

s-election sequence.

Notes.

I’ho

third

unit (code of

volumetric flow

direction)

changes

a^s shown

below':

13 ----- *■ F -------- ► K ------

-